beautypg.com

Edwards Signaling 435EX User Manual

Description, Installation, Electrical specifications

background image

Class

Zones

Divisions

Groups

I

1 and 2

B, C and D

I

1 and 2

IIA and IIB

II

1 and 2

E, F, and G

III

1 and 2

VIBRATING BELLS

AC

DC

CAT. NO.

RATED

VOLTAGE

50/60 HZ

CURRENT

(RMS)

CAT. NO.

RATED

VOLTAGE

CURRENT

340EX-6G5

24V AC

0.21A

435EX-6C1

6V DC

1.52A

340EX-10G5

24V AC

0.21A

435EX-6E1

12V DC

0.52A

340EX-6N5

120V AC

0.041A

435EX-10E1

12V DC

0.52A

340EX-8N5

120V AC

0.041A

435EX-6G1

24V DC

0.21A

340EX-10N5

120V AC

0.041A

435EX-8G1

24V DC

0.21A

340EX-6R5

240V AC

0.021A

435EX-10G1

24V DC

0.21A

340EX-10R5

240V AC

0.021A

435EX-6K1

48V DC

0.11A

435EX-8K1

48V DC

0.11A

435EX-6P1

125V DC

0.040A

435EX-8P1

125V DC

0.040A

435EX-6S1

250V DC

0.023A

435EX-8S1

250V DC

0.023A

SINGLE STROKE BELLS

AC

DC

CAT. NO.

RATED

VOLTAGE

50/60 HZ

CURRENT

(PEAK)

CAT. NO.

RATED

VOLTAGE

CURRENT

(PEAK)

332EX-6G5

24V AC

3.4A

333EX-6G1

24V DC

3.5A

332EX-10G5

24V AC

3.4A

333EX-10G1

24V DC

3.5A

332EX-6N5

120V AC

0.43A

333EX-6P1

125V DC

0.52A

332EX-10N5

120V AC

0.43A

333EX-6S1

250V DC

0.26A

332EX-6R5

240V AC

0.20A

332EX-10R5

240V AC

0.20A

NOTE: The first one or two numbers following the dash in the catalog number designate

the gong size, i.e., 340EX-6G5 is a catalog series 340EX bell with a 6" gong.

Description

Description

Description

Description

Description

Edwards Catalog Series 332EX, 333EX, 340EX and 435EX
Adaptabel Bells are heavy duty, UL listed audible signal-
ing appliances intended for use in hazardous locations.
The 332EX and 333EX series are single stroke bells suit-
able for use in coded signaling applications such as tim-
ing, scheduling, paging, or alarm. The 340EX and 435EX
series are vibrating bells suitable for use in general sig-
naling and alarm applications. The 332EX and 340EX se-
ries are ac-powered and the 333EX and 435EX series are
dc-powered. The bells are electromechanical devices and
utilize solid state components. They are Outdoor Type 4
listed. All series of the bells are listed for installation in
the following hazardous locations:

Installation Instructions for Catalog Series 332EX, 333EX, 340EX

and 435EX Adaptabel Bells for Use in Hazardous Locations

Mechanical Specifications

Mechanical Specifications

Mechanical Specifications

Mechanical Specifications

Mechanical Specifications

Dimensions

With 6" gong ...... 7" (178 mm) H x 5" (127 mm) D
With 8" gong 9" (229 mm) H x 5 1/8" (130 mm) D
With 10" gong11" (279 mm) H x 5 1/4" (133 mm) D

Weight

With 6" gong ....................... 5 1/4 pounds (2.4 kg)
With 8" gong ............................. 7 pounds (3.2 kg)
With 10" gong ..................... 8 1/4 pounds (3.8 kg)

Installation

Installation

Installation

Installation

Installation

The following items (not supplied) are required for instal-
lation of the bell:

• 3/4" conduit to contain power supply and ground wires

• One 3/4" NPT nipple

• One conduit outlet box suitable for use in the hazardous

location

• Two fasteners up to 3/8" diameter and washers suitable

for securing bell to mounting surface.

• Two wire nuts.

The bell can be mounted to any solid surface. Install bell
as follows:

1.

See Figure 1. Remove cover from conduit outlet box.
Feed the two wires from the applicable power source

Figure 1. Installation Wiring

Electrical Specifications

Electrical Specifications

Electrical Specifications

Electrical Specifications

Electrical Specifications

P-047550-0585 ISSUE 6 © 2005

CHESHIRE, CT 203-699-3300

CUST. SERV. FAX

203-699-3365

TECH SERV. FAX

203-699-3078

This manual is related to the following products: