beautypg.com

Testing, Wiring, Troubleshooting – Edwards Signaling 291-F6 User Manual

Page 3: General specifications

background image

Testing

After mounting the switch and actuator, test the switch for proper operation. Test with
circuit disconnected from source and load. For multiple switches in series, test one
switch at a time with all other guard doors closed. Then:

1. Hook the black and white leads of the switch to an Ohmmeter. Move the gate or door

open and closed several times slowly. At all times the meter should read O.L.
or “open.”

2. Hook the Ohmmeter to the black and red leads of the switch. Move the door or gate

open and closed. The meters should read O.L. when the actuator is away and it
should read less than 1 Ohm when the actuator is in range.

3. Hook the Ohmmeter to the white and red leads of the switch. Move the door or gate

open and closed. The meter should read 11–14 ohms (F6 model) and 500-100 ohms
(F7 models) when the actuator is away and it should read O.L. when the actuator
is in range.

Wiring

1. After the switch and actuator have been mounted and tested, wire the FailSafe

GuardSwitch

as shown in Figure 3.

2. For wiring 2 to 10 FailSafe GuardSwitches

in series, see Figure 4. (Do not exceed

10 switches in a series).

3. Failure to install in-line fuse voids warranty.

Troubleshooting

If the in-line fuse blows or the GuardSwitch

remains open:

1. Check the application for premature failure caused by inrush-currents, tampering,

excessive vibration and misalignment.

2. Disconnect all three wires of GuardSwitch

and test according to testing

instructions, steps 1-3.

3. If the GuardSwitch

fails any of the three tests, it must be replaced.

4. Replace the in-line fuse if blown.

General Specifications

Enclosure

Seamless 304 Stainless Steel

Temperature Range

-40

°

F to 150

°

F (-40

°

C to 65

°

C)

Environmental

Hermetically Sealed Contact Switch

Encapsulated in Polyurethane

NEMA Rating

1, 2, 3, 4, 4X, 5, 6, 12

Protection Class

IP 67

Response Time

5 msec

Life Cycles

100,000 Under Full Load;

Up to 200,000,000 Under Dry Circuit

Lead Types/O.D.

SJTOW-A (K) 18/3 AWG/0.33" (0.83cm)

UL/CSA

All Models

Note: The 291-F6 has a patented “watch-dog” circuit which, when switch failure
occurs, the fused watch-dog circuit will draw 2.5 Amps. The voltage supply must have
a current capacity of 2.5 Amps. This results in an open, fail-safe condition.

File E 115761

LR89176

GE Security Industrial

GuardSwitch

TM

Series 200

www.ge-security.com/industrial