Ge security industrial, General specifications, Ordering/electrical specifications – Edwards Signaling 126 GuardSwitch User Manual
Page 2
©2004 GE Security Industrial. GE Security Industrial reserves the right to change specifications without notice.
I-3885-0404 11317 Rev E
www.ge-security.com/industrial
12345 SW Leveton Drive
Tualatin, OR 97062
Phone: 800-247-9447
Fax: 503-691-7563
GE Security
Industrial
General Specifications
Enclosure
ABS Plastic with Protective PVC
Switch Sleeve
Temperature Range
-40
°
F to 122
°
F (-40
°
C to 50
°
C)
NEMA Rating
1, 2, 3, 4, 4X, 5, 6, 12
Protection Class
IP 67
Response Time
10 msec
Life Cycles
100,000 Under Full Load;
Up to 200,000,000 Under Dry Circuit
Lead Types/O.D.
12 AWG (AX)/0.13" (0.33cm)
Flex Conduit (X)/0.58" (1.5cm)
UL/CSA Certified
All Models
Ordering/Electrical Specifications
PART NUMBER
CONTACT
1
LOAD RATING
SWITCHING VOLTAGE
SWITCHING CURRENT
SENSE RANGE
2
BREAK RANGE
LEAD LENGTH
CONFIG.
AC/DC
MAXIMUM, AC/DC
MAXIMUM, AC/DC NOMINAL
NOMINAL
NOMINAL
126-EY-01AX
4
N.C./
150VA/NA
NA
1.25A
3
@120V
NA
1.0"(2.5cm)
1.5"(3.8cm)
1'(0.3m)
126*-EY-03AX
4
N.C./
150VA/NA
NA
1.25A
3
@120V
NA
1.0"(2.5cm)
1.5"(3.8cm)
3'(0.9m)
126*-EY-06AX
4
N.C./
150VA/NA
NA
1.25A
3
@120V
NA
1.0"(2.5cm)
1.5"(3.8cm)
6'(1.8m)
126-EY-06X
4
N.C./
150VA/NA
NA
1.25A
3
@120V
NA
1.0"(2.5cm)
1.5"(3.8cm)
6'(1.8m)
126-3Y-01AX
N.C.
100VA/84W
3.0A@34V
3.0A@28V
0.5"(1.3cm)
1.0"(2.5cm)
1'(0.3m)
126-4Y-01AX
SPDT
100VA/84W
3.0A@34V
3.0A@28V
0.5"(1.3cm)
1.0"(2.5cm)
1'(0.3m)
126-7Y-01AX
N.0.
100VA/84W
3.0A@34V
3.0A@28V
0.5"(1.3cm)
1.0"(2.5cm)
1'(0.3m)
126-8Y-01AX
4
N.C./
150VA/NA
NA
1.25A
3
120V
NA
0.5"(1.3cm)
1.0"(2.5cm)
1'(0.3m)
126-8Y-06X
4
N.O./
150VA/NA
NA
1.25A
3
120V
NA
1.0"(2.5cm)
1.5"(3.8cm)
6'(1.8m)
126-8Y-03AX
4
N.O./
150VA/NA
NA
1.25A
3
120V
NA
1.0"(2.5cm)
1.5"(3.8cm)
3'(0.9m)
126*-EY-03AX
4
N.C./
150VA/NA
NA
1.25A
3
120V
NA
1.0"(2.5cm)
1.5"(3.8cm)
3'(0.9m)
126-Y
Actuator Only
Included with all switches unless otherwise noted.
Warning— Each electrical rating is an individual maximum and cannot be exceeded!
1
Configuration with actuator away from the switch
2
Proximity of ferrous materials usually reduces sense range — typically by 50%. The shape and type of material cause a wide diversity of effects.
Testing is required to determine actual sense range for specific applications.
3
Can withstand inrush surge up to 4 Amps. Voltage Drop 1.5V. Minimum switch current 30mA.
4
Maximum 25 switches in series.
File E115761
LR89176
New York Calendar #40018
End-to-End
Side-by-Side
OK
OK
NO
Perpendicular
OK
Figure 4
Barrel Switch Mounting Configurations
“T”
Three configurations are appropriate for recessed interlock applications. Moving the
actuator parallel to the switch can result in on/off/on signal if the actuator passes by
the switch rather than coming to rest in proximity to it. This is NOT a recommended
configuration for interlock/position applications. "T" configuration results
in non-actuation.
1
2
Customer Load
Relay SPST
Min 120VAC/15A
Fuse & Holder
UL rated relay
recommended
when used in a
branch circuit
Neutral
(White)
Line
(Black)
4
2
1
3
Black
White
126 Switch
Figure 3
triac
output
triac
output
triac
output
triac
output
triac
output
Note: Before making electrical connections be sure that power is off. Electrical
connections are black to line and white to load (bulb).
triac
output
triac
output
triac
output