1.3 Modular Mechanical Design

The Model DM-700 Sensor Assembly is completely modular and is made up of four parts (See Figure 5 for
Assembly Break-away):

1) DM-700 Intelligent Transmitter Module (ITM)
2) Intelligent Plug-in Sensor (varies by gas type and range)
3) Model DM-700 Splash Guard Adapter
4) Splash Guard.

NOTE: All metal components are constructed from electro polished 316 Stainless Steel in order to maximize
corrosion resistance in harsh environments.

Housing Bottom
Locking Set-Screw

Splash Guard

Intelligent ransmitter Module (ITM)
Microprocessor controlled circuit

encapsulated in an explosion proof
housing

Splashguard

Adapter

Plug-In
replaceable
Sensor Cell

Magnetic
Programming
Switches

Lens and LCD
Display

Interconnect

Wiring

O-Rings