background image

Model DM-700

DM-700 Instruction Manual

Rev. 4.0

Page 38 of 48

Electrical Specifications

Input Voltage:

11-30 VDC

Power Consumption:

Normal operation = 30mA (<0.75 watt); Maximum = 50mA (1.2 watts)
Inrush Current = 1.67A @ 24V

RFI/EMI Protection:

Complies with EN61326

Analog Output:

Linear 4-20mA DC current
1000 ohms maximum loop load @ 24VDC
0 mA

All Fault Diagnostics

2 mA

In-Calibration

4-20 mA

0-100% full-scale

22 mA

Over-range condition

Serial Output:

RS-485 Modbus™ RTU
Baud Rate 9600 BPS (9600,N,8,1 Half Duplex)

Status Indicators:

4-digit LED Display with gas concentration, full-script menu
prompts for AutoSpan, Set-up Options, and Fault Reporting

Faults Monitored:

Loop Fault, Input Voltage Fault, Missing Sensor Fault,
Zero Fault, Processor Fault, Memory Fault, Calibration Fault(s)

Cable Requirements:

Power/Analog: 3-wire shielded cable
Maximum distance is 13,300 feet with 14 AWG

Serial Output: 2-wire twisted-pair shielded cable specified for RS-485 use
Maximum distance is 4,000 feet to last sensor

Mechanical Specifications

Length:

7.6 inches (190 mm), Includes Splashguard

Width:

2.2 inches (55 mm)

Weight:

2.5 lbs (1.2 Kg)

Mechanical Connection:

¾” Male NPT threaded connection

Electrical Connection:

Five 18 gauge wire leads - 5.5” long