Avigilon Control Center 5 System Integration Guide with Gallagher Command Centre
11
Gallagher Camera Setup
1.
In the Gallagher Command Centre, open the External Systems Master List
Window.
2.
Right-click the window and select New > DVR System Camera.
3.
In the General tab, name the Avigilon camera.
4.
Select the Setup tab, and complete the following fields:
o
DVR System: select the Avigilon server the camera is connected to.
o
Identification: enter the Logical ID assigned to the camera in the
Avigilon system. See
Assigning Logical IDs to Cameras
more information.
5.
Select the Event Response tab then select an Alarm Zone for all Events for
the camera.
6.
Click OK.
Testing the Connection
Once the cameras and software have been configured to support the integration, test the
connection to confirm that the integration was successful.
In the Gallagher Command Centre, perform the following:
•
In the External Systems Master List Window, right-click an Avigilon camera and
select Watch.
If you are able to watch live video, the connection was successful.