Alarm monitoring in avigilon control center client – Avigilon Gallagher Command Center 7 Integration User Manual
Page 13
Avigilon Control Center 5 System Integration Guide with Gallagher Command Centre
9
8.
Select the Messages tab.
9.
In the FT Controller API strings area, enter the alarm trigger information in the
On field in the following format:
alarmTrigger
For example: alarmTrigger 192.168.128.162 burg alarm
NOTE: The case sensitive alarm name is configured in the Avigilon Control Center Client.
See
on page 7 for more information.
10. You have the option of adding an acknowledgement string in the Off field to
automatically acknowledge the alarm in the Avigilon system. Use the following
format:
alarmAck
For example: alarmAck 192.168.128.162 normal burg alarm
NOTE:
can be set to
normal
,
grant
or
deny
. The grant and deny
settings can only be used when the alarm requires user confirmation to activate a
digital output. See
on page 7 for more information.
Alarm monitoring in Avigilon Control Center Client
All alarms configured in the Avigilon Control Center can be monitored in the Avigilon
Control Center Client. See the
Avigilon Control Center Client User Guide
for more
information.