Click)
to exit without saving.
 
Following is a brief description for each item and its specific operations: 
 
Size (GB) – the total HDD storage in GB (Giga-Byte) for Alarm Record and 
Normal Record respectively. This item is just for information. Please refer to 
Section 6.6.1
for more detailed information and setup of each individual HDD.
Please note that if the total alarm record size is zero, the alarm video/audio 
will be recorded in normal record partition. Please note that if the total 
normal record size is zero, the normal video/audio will be recorded in alarm 
record partition.
Auto Overwrite – automatic overwrite of the recorded video/audio from HDD#1 
when the Alarm/Normal Record disk drive capacity reaches the end of the last 
HDD. If Auto Overwrite is disabled and the Alarm/Normal Record disk drive 
capacity reaches the end, the system will not overwrite the recorded video/audio, 
and hence not record Alarm/Normal video/audio, until the user presses the 
Alarm
Reset
button. Press
ENTER
or
+/-
to check/uncheck this item. The default
setting is “ˇ
ˇ
ˇ
ˇ” - checked.
HDD Full Action – actions when Alarm/Normal Record disk drive capacity 
reaches the end of the last HDD. Press 
ENTER
or
+/-
to check/uncheck this
item. The default setting is “ˇ
ˇ
ˇ
ˇ” - checked.
Duration – response duration to define at most how long (in seconds) the Alarm 
Out relay and the Buzzer will keep being triggered after the corresponding 
partition, Alarm Record or Normal Record, is full. Press 
+/-
buttons to adjust the
value (3 seconds - 60 minutes, discrete, ‘-‘ for ‘Forever’).
Alarm Out – to define which Alarm Output will be triggered when the 
corresponding partition, Alarm Record or Normal Record, is full. Press 
+/-
buttons to select none (N/A) or one of the Alarm Outputs (1-4).
Buzzer – to activate the internal Buzzer or not when the corresponding partition, 
Alarm Record or Normal Record, is full. Press 
ENTER
or
+/-
to check/uncheck
this item. The default setting is “ˇ
ˇ
ˇ
ˇ” - checked.
Log – to log to event logs or not. Press
ENTER
or
+/-
to check/uncheck this
item. The default setting is “ˇ
ˇ
ˇ
ˇ” - checked.
E-mail – to send the event e-mail to remote station or not. The e-mail will be 
sent to the predefined receivers when the event is triggered. Press 
ENTER
or
+/-
to check/uncheck this item. The default setting is “–
–
–