iMpORTANT: If pump fails to prime within five minutes:
Turn power off at the breaker box and check all pipe connections for leaks. all connections must be
water and air tight in order for pump to operate.
pUMp pRiMiNG AND STARTUp
Discharge
to
Home
Water Level
1-1/4 in. Foot Valve
1 in.
Discharge Pipe
1-1/4 in.
Suction Pipe
Suction
Lift
40 ft.
Max.
1 in.
Pressure Pipe
1 -1/4 in. to 1 in. Male Adapter
1 in. Pipe
7. Check suction pipe for any sagging. Support
suction pipe in a straight line to the pump.
NOTe: Look for leaks or a milky color in the
discharged water, which indicates an air leak.
Re-prime if necessary, following steps 1 through
6 above. Reset breaker at the breaker box. all
connections must be water and air tight in order
for pump to operate.
7
CARe AND MAiNTeNANCe
Winterizing
CAUTiON: Drain the entire system if
there is danger of freezing.
1. To drain pump, remove the drain plug
located on the front of pump and the priming
plug located on the top of pump.
Priming
Plug
Drain
Plug
1