TANk TO HOUSe CONNeCTiON
5. attach the pipe from the pump to the tee
installed in Step 4. Then, from the tee,
install 3/4 in. pipe and optional shut off
valve (not included) to connect tee to
house plumbing.
IL1369
Glue
To House
Plumbing
From Pump
Shut off valve
5
pUMp eleCTRiCAl CONNeCTiONS
WiRe SiZe CHART
Distance
from Motor to
Meter
Recommended Copper wire
and Fuse Sizes
Single Phase Motors
1/2 HP
3/4 HP
1 HP
115
Volt
230
Volt
115
Volt
230
Volt
115
Volt
230
Volt
0-50 Ft.
50-100 Ft.
100-150 Ft.
150-200 Ft.
200-300 Ft.
14
12
12
12
10
14
14
14
14
14
14
12
10
10
8
14
14
12
12
10
12
12
10
8
6
14
14
12
12
10
Fuse Size
(amps)
15
15
15
15
20
15
WARNiNG:
• always disconnect pump from electricity before
performing any work on the motor.
• Under-sized wiring can cause motor failure and even
fire. Use proper wire size specified in the Wire Size
Chart.
• Replace damaged or worn wiring cord immediately.
• Do not kink power cable and never allow the cable
to come in contact with oil, grease, hot surfaces, or
chemicals.
• The pump must be properly grounded using the proper
wire cable with ground.
CAUTiON:
• Protect the power cable from coming in contact with
sharp objects.
• All wiring should be performed by a qualified electrician in accordance with the National
Electric Code and local electric codes.
• Connect the pump to a separate electrical circuit with a dedicated circuit breaker. Refer to the
wire Size Chart for proper fuse size.
6.
iMpORTANT: air pressure in the tank
must be 2 PSI lower than the “cut-in” of
the pressure switch. Pump has a 20/40
PSI pressure switch, so tank pressure
must be set at 18 PSI. Locate the air
valve/stem on the tank and check
pressure with a tire gauge (not included).
If air needs to be removed, press down on
valve to bleed off air. Use a tire pump or
air compressor to add air if needed.
Tire gauge
Tank
Air Valve/Stem