Breaker box – Star Water Systems SJ10 User Manual
Page 18
![background image](/manuals/365192/18/background.png)
18
95 North Oak Street • Kendallville, IN 46755 • © 2014 Star Water Systems. All rights reserved.
pUMp pRiMiNG AND STARTUp
4. Check to be sure water in the cavity of pump
stays constant. If water level goes down, it
could indicate a leak in the foot valve, check
valve or suction pipe.
Water
Level
Check for
Leaks
4
5. Once pump is filled, wrap the discharge tee
plug and priming plug threads with thread
tape and thread into pump. Tighten with
wrench.
NOTE: Before turning on breaker, open several
outlets or faucets to allow water flow during
priming.
Priming plug
or pressure
gauge
Vent plug
5
20
20
20
20
IL1339
Breaker Box
6. Turn on breaker to start pump.
iMpORTANT: If the pump hums instead of
pumping or turns off repeatedly, shut pump off
immediately.
Check voltage. Make sure your incoming voltage
matches the pump wiring voltage. See PUMP
ELECTRICaL CONNECTIONS.
6
3. Be sure all pipes are filled when priming.
Depending on the length of suction pipes,
several gallons will be needed to fill the entire
system.
3