Note: Raw data types
+ Rx Raw
(and/or
+ OBN
for Ashtech users) are
only available when
Receiver Dynamics
is set to
Static on occupy
.
Note: All receivers need to be in static mode to record Rx. Raw, and
some receivers always record Rx Raw when in static mode. If the
combination of settings you select is not compatible for your receiver,
you will be prompted to change the settings.
.
4.
Select the
Accept
filter.
¾
Fixed RTK only
will reject all positions that are not fixed.
Code, Float, or Fix
will allow you to accept any position
accept autonomous or invalid data.
Note: If you are collecting simultaneous RTK and post processing
data, you can accept an autonomous position based on the
Job/Settings, Post Process card. If enabled, you will either be
prompted to put the autonomous position on a separate layer, or it
will automatically be stored on a separate layer.
5.
Set the
Acceptance Criteria
.
¾
Acceptance
Criteria
is used to check each solution you
accept. If the measurement exceeds the criteria, you will
be prompted to accept or reject the point. Check this box
if you want to enable criteria checking. Enter a maximum
value for HRMS, VRMS, and/or PDOP in the fields. Only
fields with a non-zero value will be used for criteria
checking.
¾
To accept data points automatically using the selected
criteria, check the
Auto Accept
box at the bottom of this
page.
6.
Tap