Manual Entry of Parameters
Manual entry of parameters is used when you already know the
appropriate horizontal and vertical localization parameters for a site.
Use manual entry of parameters to key in the site parameters and set
it as the current projection record.
If you already know the scale, rotation, translation, and origin for a
horizontal site, or if you know the slope, shift and origin of a vertical
site, you can manually set the localization parameters.
1.
After receiver setup, go to Projection from the Survey menu.
2.
Tap
6ROYH /RFDOL]DWLRQ to open the Solve Localization wizard and
then tap
0DQXDO (QWU\!.
3.
Enter the
Scale
,
Rotation
,
Translations
, and
Origin
of the
horizontal system.
4.
Enter the
Slope N
,
Slope E
,
Separation
, and
Origin
of the vertical
adjustment.
5.
Tap
6ROYH! to show the horizontal and vertical parameters
entered.
6.
Review the results and tap
$FFHSW when you are done.