beautypg.com

Error codes – Hired-Hand Emergency Back-Up and Alarms: Evolution Back-Up User Manual

Page 15

background image

Part No. 4801-5309 rev 10-05

Evolution Back-Up

15 of 16

14. Error

Codes

If your controller is displaying an “E1” or “E2”, etc. the controller has recorded an error.
The controller records errors based on sensor reading and the communications links. When any of these
errors occur an alarm will be generated.

Error Codes for the Evolution Back-Up System































Error Code

Description

Explanation

E1

Sensor 1 Error

Usually indicates a shorted sensor
wire. Check sensor resistance.

E2

Sensor 2 Error

Usually indicates a shorted sensor
wire. Check sensor resistance.
Note: If Sensor 2 is switched
OFF, then this error code is not
active.

E3

Sensor 1 and Sensor 2

Sensors 1 and 2 both shorted.

LnE

Local Network Error

The Back-Up has lost
Communications with the Master
Controller. NOTE: During this
condition the Back-Up will run
Cool 1 on a 5 minute timer.

LnO

Local Network Override Error

The Master Controller has lost
communications with one or
more of the StageUnits (PCB
168) connected to it. In this
condition the Back-Up takes
control over the stages.

This manual is related to the following products: