Part No. 4801-5098 Farm Hand Vent Master 37

Note: There are other error codes that are possible since there are

too many possibilities to list. Any error codes that are
encountered other than the ones listed above should be
reported to Hired Hand to determine the cause of the error.

16.2 Possible Solutions

Sensor Error

If any of the sensors are bad try the following:

Reset the controller by taking power away at the breaker, or unplugging it.

Determine which sensor is bad, then check the connection inside the controller door. If the
error is for sensor 3, read the section below to determine alternate course of action.

Determine which sensor is bad, then check the sensor that is hanging in the house to make
sure that it has not been damaged.

Replace the bad sensor.

Sensor 3 Error

Check to see if you are using sensor 3. If not, deactivate it using switch number 4 (SWX-4)
on the status switch bank located on the back of the controller’s door.

Variable Speed Fans not Operating

If the variable speed fans are not operating properly, do the following:

Try a different motor curve (P11).

If the system is using 110 VAC, make sure that the neutral wire is connected to L1, and the
hot wire is connected to L2.

Make sure a proper earth ground is connected to the controller.

Cycle Error

If a Cycle error has occurred, it will flash the error code until the error is manually reset by
removing power from the controller and then reapplying power.

If a Cycle error is indicated, check the operation of the timer fan.

Also, check the operation of the inlets.

High Pressure Error

If a High Pressure error has occurred, it will flash the error code until the error is manually
reset.

If a High Pressure error is indicated, check the operation of the inlets.

Low Pressure Error

If a Low Pressure error has occurred, it will flash the error code until the error is manually
reset.