11.2 Connecting Equipment Directly to the Controller










































Warning: Do not connect more than 12 amps of load to a single stage!

Warning: Check that the stage jumpers are removed when connecting a load

directly to the controller.

Note: Hired-Hand, Inc. recommends the use of an external contactor or relay

panel to drive equipment.

STAGES OUT

Inset B

Inset A

Remove stage jumpers if

using a separate power

supply for each stage.

St
ag
es

IN

5

4

3

2

1

IN

ST
AG

ES

3

2

1

SENSORS

+1

2

V

SI

G

N

AL

GN

D

RE

T

HO

T

L1

L2

EA

R

T

H

GN

D

HI

5

4

3

2

1

FA

N2

FA

N1

IN

VAR FANS

STAGES OUT

SWX1

PRESSURE

AC POWER

HH NET

Curtain 1

Curtain 2

Clo

s

e

Op

e

n

Hot

Clo

s

e

Op

e

n

Hot

Signal

Signal

4 Stage Controller

Inset A

Inset B

Breaker

Panel

Hot

Neutral