10 variable curves jumpers – Hired-Hand Evolution Series 3000/3001: Variable Output With Override Pot User Manual
Page 8
![background image](/manuals/362879/8/background.png)
Part No. 4801-5318 Rev 4-06
Evolution Variable Output
Page 8 of 14
The Sunrise/Sunset Pot is for lights only and will function only in a stand-alone application with a normally open timer or dry
contact switch connected. See wiring diagrams for more specific information.
NOTE: The timer or dry contact switch for a stand-alone application is not included with the Variable Output unit.
The Sunrise/Sunset Pot allows settings from 0 to 30 minutes. If 0 is selected, the lights will turn ON immediately when the
timer/contact switch is closed and will turn OFF immediately when the timer/contact switch is opened. If any other interval is
selected, the lights will take the selected amount of minutes to go from low intensity to full light intensity after the contact is closed
and from full intensity to low light intensity after the contact is opened.
6.10 Variable Curves Jumpers
The Variable Curve jumpers are for selecting the light setting or fan motor curves. The jumper must be placed in the appropriate
position based on the equipment being varied.
See Curve and Condition Table below for each jumper setting and description.
Curve Condition
LIGHT
For use with incandescent light bulbs.
FAN0
This curve is optimized for use with Hired-Hand’s line of Funnel Flow Fans that are 24” or less.
Also, the line voltage must be Single Phase.
FAN1
This curve lends itself better to operation of 36” fans. The power distributed at each percentage
is somewhat greater than that of curve 0. Therefore, the speed will be a little greater than that of
Curve 0.
FAN2
This curve is for 3-phase systems. Its purpose is to shift the voltage curve to give a much higher
power from the varied phase. Conditions that would warrant the use of this curve is a variable
speed fan that varies a great deal from 100% speed to 95% speed.