System 1000 Power Curtain

Features

••

5

Shutoff on Open -- If "yes" is selected, the variable speed fans will

not operate when the curtains are opened.

In the Example at the right, the system was
programmed as follows:

Max Speed

100%

Max Offset

Min Speed

40%

Min Offset

-10º

Target Temp

75º

Light Strip Control

This feature is added for those applications which require the

restriction of natural light for production. When light strip control is
activated, it will ask for a time to begin, inches to drop, inches first
drop, and end time. "Inches to Drop" is the distance from the top of the
curtain opening to the bottom of the light strip. The curtains will not
rise above this setting during light hours. "Inches first Drop" should be
the distance you desire the curtain to open on the first drop from dark
to light.

Nite Vent Program

This program is only operative if the light strip control is enabled.

When using this program, the controller will allow natural ventilation
during the hours you select. This will save on energy costs by
minimizing the use of power ventilation when it is dark. The controller
will ask for a "Begin Cycle PM" and an "End Cycle AM". Remember
when setting up the system to select times before sunrise.

Night Vent Program Hours

Light Control Hours

12a.m.

12 noon

12 p.m.

4:30

8:00

4:00

9:00

40%

100%

75

65