Changing the warning temperature threshold – Brocade FastIron WS Hardware Installation Guide User Manual
Page 53

Brocade FastIron WS Hardware Installation Guide
43
53-1002498-02
Managing FastIron WS temperature settings
4
To display the system log, enter the following command at any CLI level.
Changing the temperature warning and shutdown levels
To change the temperature at which the device sends a warning, enter a command such as the
following at the Privileged EXEC level of the CLI.
Brocade#temperature warning 47
Syntax: temperature warning
The
To change the shutdown temperature, enter a command such as the following at Privileged EXEC
level of the CLI.
Brocade#temperature shutdown 57
Syntax: temperature shutdown
The
Changing the warning temperature threshold
You can change the warning temperature using the following command. The valid range is 0 –
125
C.
The FastIron WS devices will automatically reset and reload the software when the internal
temperature reaches or exceeds the configured shutdown level for five minutes. This release also
adds the capability for the system to register negative temperature settings.
To change the temperature at which the device sends a warning, enter a command such as the
following at the Privileged EXEC level of the CLI.
Brocade#temperature warning 47
Syntax: temperature warning
The
Brocade#show log
Syslog logging: enabled (0 messages dropped, 0 flushes, 0 overruns)
Buffer logging: level ACDMEINW, 8 messages logged
level code: A=alert C=critical D=debugging M=emergency E=error
I=informational N=notification W=warning
Static Log Buffer:
Dynamic Log Buffer (50 entries):
at 0 days 0 hours 2 minutes 0 seconds, level alert
Temperature 48.0 C degrees, warning level 45.0 C degrees, shutdown level 55.0 C
degrees
at 0 days 0 hours 1 minutes 0 seconds, level alert
Temperature 40.0 C degrees, warning level 35.0 C degrees, shutdown level 45.0 C
degrees