4

To display the system log, enter the following command at any CLI level.

Changing the temperature warning and shutdown levels

To change the temperature at which the device sends a warning, enter a command such as the
following at the Privileged EXEC level of the CLI.

Brocade#temperature warning 47

Syntax: temperature warning

The can be 0 – 125.

To change the shutdown temperature, enter a command such as the following at Privileged EXEC
level of the CLI.

Brocade#temperature shutdown 57

Syntax: temperature shutdown

The can be 0 – 125.

Changing the warning temperature threshold

You can change the warning temperature using the following command. The valid range is 0 –
125

C.

The FastIron WS devices will automatically reset and reload the software when the internal
temperature reaches or exceeds the configured shutdown level for five minutes. This release also
adds the capability for the system to register negative temperature settings.

To change the temperature at which the device sends a warning, enter a command such as the
following at the Privileged EXEC level of the CLI.

Brocade#temperature warning 47

Syntax: temperature warning

The can be 0 – 125.

Brocade#show log
Syslog logging: enabled (0 messages dropped, 0 flushes, 0 overruns)
Buffer logging: level ACDMEINW, 8 messages logged
level code: A=alert C=critical D=debugging M=emergency E=error
I=informational N=notification W=warning

Static Log Buffer:

Dynamic Log Buffer (50 entries):

at 0 days 0 hours 2 minutes 0 seconds, level alert
Temperature 48.0 C degrees, warning level 45.0 C degrees, shutdown level 55.0 C
degrees

at 0 days 0 hours 1 minutes 0 seconds, level alert
Temperature 40.0 C degrees, warning level 35.0 C degrees, shutdown level 45.0 C
degrees