Managing FastIron WS temperature settings

4

Syntax: show chassis

Displaying Syslog messages for temperature on the FastIron WS

The software sends a Syslog message and an SNMP trap if the temperature crosses the warning or
shutdown thresholds. The following methods describe how to view the system log on the device. If
you have configured the device to use a Syslog server or SNMP trap receiver, refer to the
documentation for the server or receiver.

Brocade# show chassis

chassis

Power supply/fan/temperature

Brocade# show chassis
Power supply 1 (NA - AC - Regular) present, status ok Power supply 2 not present

Fan 1 ok, speed (auto): [[1]]<->2<->3
Fan 2 ok, speed (auto): [[1]]<->2<->3

Fan controlled temperature: 50.5 deg-C

Fan speed switching temperature thresholds:

Speed 1: NM<----->53

deg-C

Speed 2:

37<----->55

deg-C

Speed 3:

50<-----> 90 deg-C (shutdown)


Sensor B Temperature Readings:

Current temperature : 50.5 deg-C
Warning level.......: 55.0 deg-C
Shutdown level......: 90.0 deg-C Sensor A Temperature Readings:
Current temperature : 42.0 deg-C Boot Prom MAC: 001b.ed7e.7040 Management

MAC: 001b.ed7e.7040 Brocade#tempera

temperature

temperature sensor commands

Brocade#temperature war

warning

Temperature at which the module sends a warning

Brocade#temperature warning 40
Brocade#
!!! Temperature is over warning level !!!

SYSLOG: <9>Jan 1 00:00:00 FWS648G Router System: Temperature 50.0 C degrees,
warning level 40.0 C degrees, shutdown level 90.0 C degrees

SYSLOG: <12>Jan 1 00:00:00 FWS648G Router System: Temperature is over warning
level

Brocade#temper

temperature

temperature sensor commands

Brocade# temperature shut 45