Brocade FastIron WS Hardware Installation Guide User Manual
Page 52

42
Brocade FastIron WS Hardware Installation Guide
53-1002498-02
Managing FastIron WS temperature settings
4
Syntax: show chassis
Displaying Syslog messages for temperature on the FastIron WS
The software sends a Syslog message and an SNMP trap if the temperature crosses the warning or
shutdown thresholds. The following methods describe how to view the system log on the device. If
you have configured the device to use a Syslog server or SNMP trap receiver, refer to the
documentation for the server or receiver.
Brocade# show chassis
chassis
Power supply/fan/temperature
Brocade# show chassis
Power supply 1 (NA - AC - Regular) present, status ok Power supply 2 not present
Fan 1 ok, speed (auto): [[1]]<->2<->3
Fan 2 ok, speed (auto): [[1]]<->2<->3
Fan controlled temperature: 50.5 deg-C
Fan speed switching temperature thresholds:
Speed 1: NM<----->53
deg-C
Speed 2:
37<----->55
deg-C
Speed 3:
50<-----> 90 deg-C (shutdown)
Sensor B Temperature Readings:
Current temperature : 50.5 deg-C
Warning level.......: 55.0 deg-C
Shutdown level......: 90.0 deg-C Sensor A Temperature Readings:
Current temperature : 42.0 deg-C Boot Prom MAC: 001b.ed7e.7040 Management
MAC: 001b.ed7e.7040 Brocade#tempera
temperature
temperature sensor commands
Brocade#temperature war
warning
Temperature at which the module sends a warning
Brocade#temperature warning 40
Brocade#
!!! Temperature is over warning level !!!
SYSLOG: <9>Jan 1 00:00:00 FWS648G Router System: Temperature 50.0 C degrees,
warning level 40.0 C degrees, shutdown level 90.0 C degrees
SYSLOG: <12>Jan 1 00:00:00 FWS648G Router System: Temperature is over warning
level
Brocade#temper
temperature
temperature sensor commands
Brocade# temperature shut 45