beautypg.com

Connecting devices to the redundant power supply – Brocade FastIron WS Hardware Installation Guide User Manual

Page 33

background image

Brocade FastIron WS Hardware Installation Guide

23

53-1002498-02

Installing a redundant power supply

2

Connecting devices to the redundant power supply

The FastIron RPS2-EIF is supported on the following devices:

FastIron WS624

FastIron WS648

The FastIron RPS12 is supported on the following devices:

FastIron FWS624-POE

FastIron FWS648-POE

To connect devices to a redundant power supply, follow these steps.

1. Connect one end of the AC cord to the AC receptacle on the device, and the other end to a

grounded power outlet. Refer to

Figure 21

.

FIGURE 21

Power receptacle

2. Connect one end of a DC cord to the redundant power receptacle on the device and the other

end to an available receptacle on the redundant power supply.

3. Repeat

step 1

and

step 2

to connect up to four devices to the redundant power supply. Refer to

Figure 22

.

4. Connect one end of the AC cord to the AC receptacle on the redundant power supply, and the

other end to a grounded power outlet.

5. Check the LEDs on the redundant power supply to ensure proper operation. On the RPS2-EIF

and RPS12, the Power LED should light up. If the LEDs do not light, refer to

“Troubleshooting”

on page 53 for more information.

100-240V, 50-60Hz 10A

RPS 1