Storage environment

Storage environment specifications

TABLE 27

Storage Temperature

Storage Humidity

Storage Altitude

40× to 70× C

(-40× to 158× F)

95% maximum,

non-condensing

3,000 meter (10,000 feet)

maximum

Cooling system and fans

The fans cool the CPU, main memory, and voltage regulators. For theBrocade FCX 624S, FCX 648S,
FCX 624S-F, FCX 624S-HPOE, and FCX 648S-HPOE switches, the fans use either a push or pull
configuration to move the air from the right side of the device to the left side of the device.

Total cooling capacity: 80 to 130 watts

Total air flow: 34.3 CFM

Operating noise: ideal 51 dB-A

For the Brocade FCX 624-E and FCX 648-E models, the air flows from the front to the rear of the
device. For the Brocade FCX 624-I and Brocade FCX 648-I models, the air flows from the rear to the
front of the device.

Total cooling capacity: 180 Watts

Total air flow: 85.2 CFM

Operating noise: ideal 60 dB-A

NOTE
Operating noise is based on the ISO 7779 standard.