beautypg.com

Displaying syslog messages for temperature, Changing temperature warning and shutdown levels – Brocade FCX Series Hardware Installation Guide User Manual

Page 80

background image

MAC 1 Temperature Readings:

Current temperature : 58.5 deg-C

CPU Temperature Readings:

Current temperature : 52.0 deg-C

Warning level.......: 75.0 deg-C

Shutdown level......: 90.0 deg-C

Boot Prom MAC : 0000.0000.0720

Management MAC: 0000.0000.0720

Syntax: show chassis

Displaying Syslog messages for temperature

The software sends a Syslog message and an SNMP trap if the temperature crosses the warning or
shutdown thresholds. The following methods describe how to view the system log on the device. If you
have configured the device to use a Syslog server or SNMP trap receiver, see the documentation for
the server or receiver.

To display the system log, enter the show log command at any CLI level.

device# show log

Syslog logging: enabled (0 messages dropped, 0 flushes, 0 overruns)

Buffer logging: level ACDMEINW, 8 messages logged

level code: A=alert C=critical D=debugging M=emergency E=error

I=informational N=notification W=warning

Static Log Buffer:

Dynamic Log Buffer (50 entries):

at 0 days 0 hours 2 minutes 0 seconds, level alert

Temperature 48.0 C degrees, warning level 45.0 C degrees, shutdown level 55.0 C

degrees

at 0 days 0 hours 1 minutes 0 seconds, level alert

Temperature 40.0 C degrees, warning level 35.0 C degrees, shutdown level 45.0 C

degrees

Changing temperature warning and shutdown levels

The default warning temperatures and the default shutdown temperatures for the device are:

- Warning temperature is 85 Deg-C (measured on mainboard)

- Shutdown temperature is 90 Deg-C (measured on mainboard)

NOTE
These temperatures reflect the temperature of the board inside the device.

To change the temperature at which the device sends a warning, enter a command similar to the
following at the Privileged EXEC level of the CLI:

device# temperature warning 1 85

Syntax: temperature warning stack-id value

The stack-id can be 1 - 8.

The value can be 0 - 125

device# temperature

temperature temperature sensor commands

device# temperature warning

warning Temperature at which the module sends a warning

device# temperature warning

DECIMAL Stack Number

device# temperature warning 1 87

device# show chassis

The stack unit 1 chassis info:

Displaying Syslog messages for temperature

78

Brocade FCX Series Hardware Installation Guide

53-1003077-01