beautypg.com

Specifying a port address, Specifying a data port, Specifying a stacking port – Brocade FCX Series Hardware Installation Guide User Manual

Page 26: Specifying a management port

background image

device(config)# show optic 1/3/1

Port Temperature Tx Power Rx Power Tx Bias Current

+----+-----------+--------------+--------------+---------------+

1/3/1 32.7421 C -002.3195 dBm -002.5947 dBm 6.212 mA

Normal Normal Normal Normal

device# show media e 1/3/1

Port 1/3/1: Type : 10G XG-ER(SFP +)

Vendor: BROCADE Version: A

Part# : 57-0000085-01 Serial#: XXXXXXXXXXXXXXX

device# show media e 1/3/2

Port 1/3/2: Type : 10G XG-USR (SFP +)

Vendor: BROCADE Version: A

Part# : 57-1000130-01 Serial#: XXXXXXXXXXXXXXX

device# show media

1/1/1:C 1/1/2:C 1/1/3:C 1/1/4:C 1/1/5:C 1/1/6:C 1/1/7:C 1/1/8:C

1/1/9:C 1/1/10:C 1/1/11:C 1/1/12:C 1/1/13:C 1/1/14:C 1/1/15:C 1/1/16:C

1/1/17:C 1/1/18:C 1/1/19:C 1/1/20:C 1/1/21:C 1/1/22:C 1/1/23:C 1/1/24:C

1/1/25:C 1/1/26:C 1/1/27:C 1/1/28:C 1/1/29:C 1/1/30:C 1/1/31:C 1/1/32:C

1/1/33:C 1/1/34:C 1/1/35:C 1/1/36:C 1/1/37:C 1/1/38:C 1/1/39:C 1/1/40:C

1/1/41:C 1/1/42:C 1/1/43:C 1/1/44:C 1/1/45:C 1/1/46:C 1/1/47:C 1/1/48:C

1/2/1:XG-CX4 1/2/2:XG-CX4

1/3/1:XG-ER 1/3/2:XG-USR

Specifying a port address

You can specify a port address for a data port, stacking port, or a management port.

Specifying a data port

The port address format is stack unit/slot/port, where:

stack unit--Specifies the stack unit ID. Range is from 1 to 8. If the device is not part of a stack, the
stack unit ID is 1.

slot--Specifies the slot number. Can be 1 or 3.

port--Specifies the port number in the slot. Range is from 1 to 24 (24-port models) or 1 to 48 (48-
port models).

This example indicates it is Stack Unit 1:

Brocade(config)# interface ethernet 1/1/2

Specifying a stacking port

The port address format is stack unit/slot/port, where:

stack unit--Specifies the stack unit ID. Range is from 1 to 8.

slot--Specifies the slot number. Default stacking ports are in slot 2 (FCX S/S-F).

port--Specifies the port number in the slot. Default stacking ports in slot 2 are ports 1 and 2.

This example shows how to specify port 2 in slot 2 of unit 3 in a stack:

Brocade(config)# interface ethernet 3/2/2

Specifying a management port

The management port number is always 1. This example shows how to specify the management port:

Brocade(config)# interface management 1

Specifying a port address

24

Brocade FCX Series Hardware Installation Guide

53-1003077-01