Brocade FCX Series Hardware Installation Guide User Manual
Page 59

Modified CLI examples for the 2-port 10 Gbps SFP+ module
The following sample output from the show module command displays an entry
for the 2-port 10G SFP+ module.
device# show module
Module Status Ports Starting MAC
U1:M1 FCX-48GS POE 48-port Management Module OK 48 0024.38c9.4d00
U1:M2 FCX-2XGC 2-port 16G Module (2-CX4) OK 2 0024.38c9.4d31
U1:M3 FCX-2SFPP 2-port 10G Module (2-SFP+) OK 2 0024.38c9.4d33
The following sample output from the show version command shows that the 2-
port 10G SFP+ module is in slot 3.
device# show version
Copyright (c) 1996-2011 Brocade Communications Systems, Inc.
UNIT 1: compiled on Oct 18 2012 at 16:01:04 labeled as FCXS07300b1
(5373912 bytes) from Primary FCXS07300b1.bin
SW: Version 07.3.00b1T7f1
Boot-Monitor Image size = 370663, Version:07.3.00T7f5 (grz07300b1)
HW: Stackable FCX648S-HPOE-PREM (PROM-TYPE FCX-ADV-U)
==========================================================================
UNIT 1: SL 1: FCX-48GS POE 48-port Management Module
Serial #: BCYXXXXXXXX
License: BASE_SOFT_PACKAGE (LID: deaHHJIhFNb)
P-ENGINE 0: type DB90, rev 01
P-ENGINE 1: type DB90, rev 01
PROM-TYPE: FCX-ADV-U
==========================================================================
UNIT 1: SL 2: FCX-2XGC 2-port 16G Module (2-CX4)
==========================================================================
UNIT 1: SL 3: FCX-2SFPP 2-port 10G Module (2-SFP+)
==========================================================================
800 MHz Power PC processor 8544E (version 0021/0022) 400 MHz bus
65536 KB flash memory
256 MB DRAM
STACKID 1 system uptime is 2 days 10 minutes 24 seconds
The system : started=warm start reloaded=by "reload"
The following is sample output of the show running-config command.
device# show running-config
!
Startup-config data location is flash memory
!
Startup configuration:
!
ver 07.3.00a001T7f1
!
stack unit 1
module 1 fcx-48-poe-port-management-module
module 2 fcx-cx4-2-port-16g-module
module 3 fcx-sfpp-2-port-10g-module
!
The following is sample output of the show media and show optic commands
with some configuration.
device# show media
1/1/1:C 1/1/2:C 1/1/3:C 1/1/4:C 1/1/5:C 1/1/6:C 1/1/7:C 1/1/8:C
1/1/9:C 1/1/10:C 1/1/11:C 1/1/12:C 1/1/13:C 1/1/14:C 1/1/15:C 1/1/16:C
1/1/17:C 1/1/18:C 1/1/19:C 1/1/20:C 1/1/21:C 1/1/22:C 1/1/23:C 1/1/24:C
1/1/25:C 1/1/26:C 1/1/27:C 1/1/28:C 1/1/29:C 1/1/30:C 1/1/31:C 1/1/32:C
1/1/33:C 1/1/34:C 1/1/35:C 1/1/36:C 1/1/37:C 1/1/38:C 1/1/39:C 1/1/40:C
1/1/41:C 1/1/42:C 1/1/43:C 1/1/44:C 1/1/45:C 1/1/46:C 1/1/47:C 1/1/48:C
1/2/1:XG-CX4 1/2/2:XG-CX4
1/3/1:XG-SR 1/3/2:XG-SR
device# show media e 1/3/1
Port 1/3/1: Type : 10G XG-SR(SFP +)
Vendor: Brocade Version: 1
Part# : PLRXPLSCS4371 Serial#: CXXXXXXXX
device(config)# op 1
Enable optical monitoring and set alarm/warn interval to 1 minute(s)
Installing the FCX Switch
Brocade FCX Series Hardware Installation Guide
57
53-1003077-01