beautypg.com

Brocade FastIron Ethernet Switch Software Licensing Guide User Manual

Page 41

background image

You can add an ICX6650-2P40G-POD license to any configuration. For example, you can add an
ICX6650-2P40G-POD license to a base 32-port configuration.

In a trunk formation, if there is no license upon bootup or hot swap of a unit, a port is disabled. This
does not affect the trunk formation.

A 10 GbE or 40 GbE port can be in one of the following port states:

- Error-disabled (invalid license)

- Down

- Up

A port is in an error-disabled (invalid license) state when there is no license installed in the device.
An invalid license implies that you have incorrectly installed a license that is not tied to the device.
When a physical link is established between two devices, but a license is not installed in the device,
the port remains in an error-disabled state. A port is operational only when you install the correct
license in the device.The show interface ethernet command displays the port in the
ERROR_DISABLED state because there is no license installed, and there is no physical link
between two devices. The following example output is from a Brocade ICX 6650 device.

device#show interface ethernet 1/1/33

10GigabitEthernet1/1/33 is ERR-DISABLED (invalid license), line protocol is

down

Hardware is 10GigabitEthernet, address is 748e.f80c.5f40(bia 748e.f80c.5f40)

Interface type is unknown

Configured speed 10Gbit, actual unknown, configured duplex fdx, actual

unknown

Member of L2 VLAN ID 1, port is untagged, port state is DISABLED

BPDU guard is Disabled, ROOT protect is Disabled

Link Error Dampening is Disabled

STP configured to ON, priority is level0, mac-learning is enabled

Flow Control is enabled

Mirror disabled, Monitor disabled

Not member of any active trunks

Not member of any configured trunks

No port name

A port is in a down state when there is no physical link between two devices, and a license is installed in
the device. The show interface ethernet command displays the port in the down state. The following
example output is from a Brocade ICX 6650 device.

device#show interface ethernet 1/1/33

10GigabitEthernet1/1/33 is down, line protocol is down

Hardware is 10GigabitEthernet, address is 748e.f80c.5f40(bia 748e.f80c.5f40)

Interface type is unknown

Configured speed 10Gbit, actual unknown, configured duplex fdx, actual

unknown

Member of L2 VLAN ID 1, port is untagged, port state is BLOCKING

BPDU guard is Disabled, ROOT protect is Disabled

Link Error Dampening is Disabled

STP configured to ON, priority is level0, mac-learning is enabled

Flow Control is enabled

Mirror disabled, Monitor disabled

Not member of any active trunks

Not member of any configured trunks

No port name

A port is in an up state when a physical link is established between two devices, and a license is
installed in the device. The show interface ethernet command displays the port in the up state. The
following example output is from a Brocade ICX 6650 device.

device#show interface ethernet 1/2/1

40GigabitEthernet1/2/1 is up, line protocol is up

Hardware is 40GigabitEthernet, address is 748e.f80c.5f40(bia 748e.f80c.5f40)

Interface type is 40Gig Copper

Configured speed 40Gbit, actual 40Gbit, configured duplex fdx, actual fdx

Configured mdi mode AUTO, actual none

Member of 1 L2 VLANs, port is tagged, port state is FORWARDING

BPDU guard is Disabled, ROOT protect is Disabled

Link Error Dampening is Disabled

Licensing for Ports on Demand

FastIron Ethernet Switch Software Licensing Guide

39