6450 devices only, 6650 devices only, Ports 2 and 4 to 10 gbps port speed, refer to – Brocade FastIron Ethernet Switch Software Licensing Guide User Manual
Page 40: Icx 6450 devices only

STP configured to ON, priority is level0, mac-learning is enabled
Flow Control is enabled
Mirror disabled, Monitor disabled
Not member of any active trunks
Not member of any configured trunks
No port name
Configuration considerations when configuring PoD for ICX 6450
devices only
Consider the following when configuring PoD for ICX 6450 devices only:
•
By default, without a license at bootup, ports 2 and 4 come up in 10 Gbps port speed in an error
disabled state. The show interface ethernet command displays the port in the
ERROR_DISABLED state at bootup. Refer to section,
Configuration considerations when
configuring PoD on an interface
on page 37 for output examples from the show interface
ethernet command.
•
From the default state, ports 2 and 4 can be configured to 1 Gbps port speed using the speed-
duplex 1000-full-master command without a license. You do not need to reboot the switch for
the links to come up in 1 Gbps port speed.
•
If you download the ICX6450-2X10G-LIC-POD license to the device, insert the correct 10 Gbps
optic transceiver, and enter the speed-duplex 10g-full command on the interface, you can
immediately begin using ports 2 and 4 in 10 Gbps port speed. You do not need to reboot the
switch for the links to come up.
•
For any of the four uplink ports on slot 2, if you reconfigure any port from 1 Gbps to 10 Gbps port
speed, you must reload the switch to begin using the ports in 10 Gbps port speed. Until you
reload the switch, the ports will remain in an error-disabled state. The following example output
displays Ethernet port 4 in an error-disabled state.
device#show interface ethernet 1/2/4
10GigabitEthernet1/2/4 is ERR-DISABLED (Reload the switch or stack to enable
this port in 10G speed), line protocol is down
Hardware is 10GigabitEthernet, address is 0000.0082.e39c (bia 0000.0082.e39c)
Configured speed 10Gbit, actual unknown, configured duplex fdx, actual
unknown
Member of L2 VLAN ID 1, port is untagged, port state is DISABLED
BPDU guard is Disabled, ROOT protect is Disabled
Link Error Dampening is Disabled
STP configured to ON, priority is level0, mac-learning is enabled
Flow Control is enabled
Mirror disabled, Monitor disabled
Not member of any active trunks
Not member of any configured trunks
No port name
MTU 1500 bytes
300 second input rate: 0 bits/sec, 0 packets/sec, 0.00% utilization
300 second output rate: 0 bits/sec, 0 packets/sec, 0.00% utilization
0 packets input, 0 bytes, 0 no buffer
Received 0 broadcasts, 0 multicasts, 0 unicasts
0 input errors, 0 CRC, 0 frame, 0 ignored
0 runts, 0 giants
0 packets output, 0 bytes, 0 underruns
Transmitted 0 broadcasts, 0 multicasts, 0 unicasts
0 output errors, 0 collisions
Relay Agent Information option: Disabled
Configuration considerations when configuring PoD for ICX 6650
devices only
Consider the following when configuring PoD for ICX 6650 devices:
Configuration considerations when configuring PoD for ICX 6450 devices only
38
FastIron Ethernet Switch Software Licensing Guide
53-1003091-02