6
Checking the Contents of the Package
Unpack the box and check the contents before operating the
instrument. If some of the contents are not correct or missing or
if there is physical damage, contact the dealer from which you
purchased them.
µR20000 Recorder
A name plate is affixed to the case. Check that the model name
and suffix code given on the name plate on the rear panel match
those on your order.
MODEL
SUFFIX
SUPPLY
STYLE
FREQUENCY
NO.
MAC
TAG NO.
TAG NO.
TAG NO.
TAG NO.
NO. (Instrument Number)
When contacting the dealer from which you purchased the
instrument, please give them the instrument number.
MODEL and SUFFIX Code
Model
Suffix
Code
Optional
Code
Description
437101
µR20000 1 pen recorder
437102
µR20000 2 pen recorder
437103
µR20000 3 pen recorder
437104
µR20000 4 pen recorder
437106
µR20000 6 dot recorder
437112
µR20000 12 dot recorder
437118
µR20000 18 dot recorder
437124
µR20000 24 dot recorder
-2
English/German/French & deg F/DST
/A1
Alarm output relay 2 points
1
/A2
Alarm output relay 4 points
1
/A3
Alarm output relay 6 points
1
/A4
Alarm output relay 12 points
1, 2
/A5
Alarm output relay 24 points
1, 2
/C3
RS-422A/485 interface
3
/C7
Ethernet (10BASE-T) interface
3
/F1
Fail/Chart end detection and output
2
/H2
Clamped input terminal
4
/H3
Non-glare door glass
/H5D
Portable type Power cord UL, CSA st’d
7
/H5F
Portable type Power cord VDE st’d
7
/H5R
Portable type Power cord AS st’d
7
/H5J
Portable type Power cord BS st’d
7
/H5H
Portable type Power cord GB st’d
7
/M1
Mathematical function
/N1
Cu10, Cu25 RTD input
/N2
3 legs isolated RTD
4, 5
/N3
Expansion inputs
6
/P1
24 VDC/AC power supply
7
/R1
Remote control 5 points
/CC1
Calibration Correction
/BT1
Header printout
1 /A1, /A2, /A3, /A4, and /A5 cannot be specified simultaneously.
/A5 is valid on the dot models.
2 /A5 and /F1 cannot be specified simultaneously on the dot
models.
/A4 and /F1 cannot be specified simultaneously on the pen
models.
3 /C3 and /C7 cannot be specified simultaneously.
4 /H2 and /N2 cannot be specified simultaneously.
5 Valid only on the dot models.
6 14 types of input including Pt50 RTD, PR40-20, and Platinel TC.
7 /H5x and /P1 cannot be specified simultaneously.
Standard Accessories
One of these power cord types is supplied
according to the instrument’s suffix code
/H5F
/H5D
/H5R
/H5H
/H5J
Z-fold chart
paper
Ribbon
cassette
Disposable
felt pen
Plotter pen
Mounting
bracket
µR20000 Recorder
Operation Guide
IM 04P02B01-02E
Manuals for the
µR10000/µR20000
(CD-ROM)
Recording Chart
CHAR
T
Recording
Chart
CHAR
T
KOKUSAI
KOKUSAI
Part Number
Note
A1006WD
Provided when optional code /H5D is specified.
Maximum rated power voltage: 125 V
A1009WD
Provided when optional code /H5F is specified.
Maximum rated power voltage: 250 V
A1024WD
Provided when optional code /H5R is specified.
Maximum rated power voltage: 250 V
A1023WD
Provided when optional code /H5J is specified.
Maximum rated power voltage: 250 V
A1064WD
Provided when optional code /H5H is specified.
Maximum rated power voltage: 250 V
Item
1-Pen 2-Pen 3-Pen 4-Pen Dot
Z-fold chart paper
1
1
1
1
1
Ribbon cassette
-
-
-
-
1
Disposable felt pen
Red
1
1
1
1
-
Green
-
1
1
1
-
Blue
-
-
1
1
-
Violet
-
-
-
1
-
Plotter pen
Purple
1
1
1
1
-
Mounting bracket (included with
models without /H5x)
2
2
2
2
2
Power cord (included with /H5x)
1
1
1
1
1
Manuals for the µR10000/
µR20000 (CD-ROM)
1
1
1
1
1
µR20000 Recorder Operation
Guide IM 04P02B01-02E
1
1
1
1
1
Software (Sold Separately, see page 8)
Item
Model
Note
Configuration software
RXA10-01
RXA10-02
With interface unit*
* You can use the Configuration Software if you install the
interface unit to a recorder does not include the communication
function.