beautypg.com

Yokogawa µR20000 User Manual

Page 37

background image

37

IM 04P02B01-02E

Selecting the Input Type

5.

Press the

key to select

1-5V and then press the key (see “Explanation”

on page 40).

Mode=1-5V

Scales and records the

Setting Span Left

6.

Set Span left to

1.000 and press the key.

Press the

key to select the desired digit.

Press the

key to select the value.

Span left= 1.000

0.800/ 1.200V

Displays the range of Span left.

Setting Span Right

7.

Likewise, set Span right to

5.000 and press the key.

Span right= 5.000

4.800/ 5.200V

Displays the range of Span right.

Setting the Decimal Position and Scaling Left

8.

Display Scale left.

Scale left= 0.00

-200.00/ 300.00 Decima

Displays the scaling range.

9.

Press the

key to select the desired digit.

Scale left= 0.00

-200.00/ 300.00 Decima

10.

Press the

key to select space and then press the key (Scale left is set to

0.0).

Scale left= 0.0

-200.00/ 300.00 Decima

Setting Scaling Right

11.

Likewise, set Scale right to

500.0 and press the key.

Scale right= 500.0

-2000.0/ 3000.0

Displays the scaling range.

The

Setting complete screen is displayed. When this screen is displayed, the settings

entered up to then are applied.

Finishing the Settings

12.

When

Setting complete screen is displayed, press the ESC key.

The

Set=Range screen is displayed.

03-03 Channel

Setting complete

Set=Range

Input range and record

Setting the Unit

13.

Press the

key to select

Unit and then press the key.

Set=Unit

Engineering unit for l

Displays the description of setting item.

14.

Press the

key to set the first channel to

03 and then press the key.

First channel Last channel

CH=03-03

First channel 01-06

Displays the selectable range of channels.

15.

Likewise, set the last channel to

03 and then press the key.

Setting the Input Range and Alarm on Measurement Channels

* When the key or key is pressed while holding down the

SHIFT key, the operation is reversed as

when the respective key is pressed by itself.