Yokogawa µR20000 User Manual
Page 58
58
IM 04P02B01-02E
Setup Item
Pen/Dot
Selectable Range or Selections
Default Value
RS-422/485 (/C3 option)
RS-422/485 > Address
-
1 to 32
1
RS-422/485 > Baud rate
-
1200/2400/4800/9600/19200/38400
9600
RS-422/485 > Data length
-
7/8
8
RS-422/485 > parity
-
Odd/Even/None
Even
RS-422/485 > Protocol
-
NORMAL/MODBUS
NORMAL
Ethernet (/C7 option)
Ethernet > Host > Host
-
64 characters or less
Blank
Ethernet > Host > Domain
-
64 characters or less
Blank
Ethernet > Local IP > A
-
IP address
0.0.0.0
Ethernet > Local IP > M
-
IP address (Subnet mask)
0.0.0.0
Ethernet > Local IP > G
-
IP address (Default gateway)
0.0.0.0
Ethernet > DNS > DNS
-
On/Off
Off
Ethernet > DNS > P
-
IP address (Primary DNS sever)
0.0.0.0
Ethernet > DNS > S
-
IP address (Secondary DNS sever)
0.0.0.0
Ethernet > DNS > Suffix_P
-
Primary domain suffix
Blank
Ethernet > DNS > Suffix_S
-
Secondary domain suffix
Blank
Ethernet > Login > Login
-
Use/Not
Not
Ethernet > LoginSet > Level
-
Admin/User1 to User6
Admin
Ethernet > LoginSet > Register
-
On/Off
Admin and User1
are On
Ethernet > LoginSet > User
-
16 characters or less
Admin: admin
User1 to 6: user1
to user6
Ethernet > LoginSet > Password
-
4 characters or less
Administrator: 0
User1 to 6: 1 to 6
Ethernet > Timeout > Timeout
-
On/Off
Off
Ethernet > Timeout > Duration
-
1 to 120 min
1 min
Ethernet > K. Alive > Keep alive
-
On/Off
On
Calibration (/CC1 option)
Calibration > Channel
-
01 to 24
01
Calibration > Mode
-
Revise Value, Absolute Value
Revise Value
Calibration > Point
-
2 to 16
2
Cust. menu > Cust. menu
-
Not/Use
Not
Cust. menu > Password
-
Numbers and spaces within 4 digits
Blank
Cust. menu > P_Adj
-
On/Off
Off
Select menu > Set mode > Range
-
On/Off
On
Select menu > Set mode > Bias
-
On/Off
On
Select menu > Set mode > Alarm
-
On/Off
On
Select menu > Set mode > Unit
-
On/Off
On
Select menu > Set mode > Chart speed
-
On/Off
On
Select menu > Set mode > Aux
-
On/Off
On
Select menu > Set mode > Calibration
-
On/Off
On
Select menu > Set mode > Math
-
On/Off
On
Select menu > Set mode > Batch name
-
On/Off
On
Select menu > Set mode > Batch detail
-
On/Off
On
Select menu > Function > Manual print
-
On/Off
On
Select menu > Function > Setup list
-
On/Off
On
Select menu > Function > Message
-
On/Off
On
Select menu > Function > Buffer clear
-
On/Off
On
Select menu > Function > Periodic
-
On/Off
On
Batch (/BT1 option)
Batch > Batch
-
Not/Use
Not
Batch > Lot No.
-
4/6/Not
4
Batch > Dual comment
-
Not/Use
Not
Batch > MSG format
-
Not/Use
Not
Adjustment
P_Adj > P_Adj
Dot Model
Hysteresis/Zero/Full
Hysteresis
Pen Model Zero/Full
Zero
P_Adj > Pen No.
Pen Model 1/2/3/4
1
Store
End > End
-
Store/Abort
Store
Setup Items and Default Values