beautypg.com

Func key operations in operation mode, Printing measured values (manual printout), Starting the manual printout 1 – Yokogawa µR20000 User Manual

Page 50: Func=print out 3, Print=manual start

background image

50

IM 04P02B01-02E

Recording/Displaying Data

FUNC Key Operations in Operation Mode

The operations below can be carried out with the FUNC key in Operation mode.
References to the µR20000 Recorder User’s Manual (IM 04P02B01-01E) provided on
the CD-ROM are given in parentheses.

: Use the

key.

key.

Message 1

Message 2

Message 3

Message 4

Message 5

Alarm

Password

Message

Start/Stop

Reset

Reset

Ribbon exchange = End

List Start/List Stop

Setup Start/Setup Stop

Manual Start/Manual Stop

: Use the

Alarm ACK

Message

Buffer clear

Keylock

Periodic

Print out

Ribbon exchange

(section 3.12)

(section 9.1)

(section 3.10)

(sections 3.7, 3.8)

(sections 3.9, 3.10)

(section 3.13)

(section 3.11)

(section 3.4)

Pen exchange = End

Pen exchange

(section 3.3)

Math

key

FUNC

Alarm output release operation. This is displayed when the

settings are changed to use the alarm ACK operation.
Starts/stops the computation. This is displayed on models with

the computation function (/M1 option).

Resets the computation.

Executes manual printout (printout of measured values).

Executes the setting (Setting mode) printout.

Executes setting (Basic Setting mode) printout.

Prints message 1.

Prints message 2.

Prints message 3.

Prints message 4.

Prints message 5.

Clears the data waiting to be printed in the alarm printout buffer.
Clears the data waiting to be printed in the message printout buffer.

This is displayed when the settings are changed to use the key

lock function. It is used to activate or release the key lock.
Resets the computed value when printing of the report data

(average, etc.) is specified in periodic printout and restarts the

calculation of the report data from that point.

Moves the recording pen to a position that is easily accessible for

replacement on the pen model.

Moves the printer carriage near the center position when replacing

the ribbon cassette on the dot model.

Recorder version: 1.31

Printing Measured Values (Manual Printout)

The measured values of all channels are printed.

Starting the Manual Printout

1.

Press the

FUNC

key.

The

FUNC= screen appears.

2.

Press the

key to select

Print out and then press the key.

Func=Print out

3.

Press the key with

Manual Start shown on the screen.

Manual printout starts. The screen returns to the data display screen.

Print=Manual Start

Note

• When manual printout is executed, trend recording is suspended. However, the recorder

continues the measurement and alarm detection (in the background).

• When manual printout is complete, trend recording resumes.
• If an alarm occurs during the manual printout, the alarm is printed after the recording

resumes.

* When the key or key is pressed while holding down the

SHIFT key, the operation is reversed as

when the respective key is pressed by itself.