Math channel > tlog, rolling average, Math channel > color, Math channel > zone, scale – Yokogawa Button Operated MV2000 User Manual
Page 42: Math channel > bar graph, Math channel > partial, Math channel > alarm mark
Math channel > TLOG, Rolling average
Setting
Selectable Range or Choices
Default Value
First-CH, Last-CH
Numeric value (computation channel number) 101 to
124
101
TLOG
Timer type
Timer/MatchTimeTimer
Timer
Timer No.
1/2/3/4
1
Sum scale
Off, /s, /min, /h
Off
Reset
On/Off
Off
Rolling average
On/Off
On/Off
Off
Interval
1s/2s/3s/4s/5s/6s/10s/12s/15s/20s/30s/1min/2min/
3min/4min/5min/6min/10min/12min/15min/20min/
30min/1h
10s
Number of
samples
Numeric value (1 to 1500)
1
Math channel > Color
Setting
Selectable Range or Choices
Default Value
Group of channel
101–106/107–112/113–118/119–124
101-106
Color
Red/Green/Blue/B.violet/Brown/Orange/Y.green/
Lightblue/Violet/Gray/Lime/Cyan/Darkblue/Yellow/
Lightgray/Purple/Black/Pink/L.brown/L.green/
Darkgray/Olieve/DarkCyan/S.green
Colors assigned in order to
groups.
Red to orange
Math channel > Zone, Scale
Setting
Selectable Range or Choices
Default Value
First-CH, Last-CH
Numeric value (computation channel number) 101 to
124
101
Zone
Lower
Numeric value (0 to 95) %
0
Upper
Numeric value (5 to 100) %
100
Scale
Position
Off/1/2/3/4/5/6
1
Division
4/5/6/7/8/9/10/11/12/C10
10
Math channel > Bar graph
Setting
Selectable Range or Choices
Default Value
First-CH, Last-CH
Numeric value (computation channel number) 101 to
124
101
Base position
Normal/Center/Lower/Upper
Normal
Division
4/5/6/7/8/9/10/11/12
10
Math channel > Partial
Setting
Selectable Range or Choices
Default Value
First-CH, Last-CH
Numeric value (computation channel number) 101 to
124
101
On/Off
On/Off
Off
Expand
Numeric value (1 to 99) %
50
Boundary
Numeric value (minimum span value + 1 digit to
maximum span value – 1 digit)
0.00
Math channel > Alarm mark
Setting
Selectable Range or Choices
Default Value
First-CH, Last-CH
Numeric value (computation channel number) 101 to
124
101
Mark kind
Alarm/Fixed
Alarm
Indicate on Scale
On/Off
Off
Alarm mark color > Alarm 1 to 4
Red/Green/Blue/B.violet/Brown/Orange/Y.green/
Lightblue/Violet/Gray/Lime/Cyan/Darkblue/Yellow/
Lightgray/Purple/Black/Pink/L.brown/L.green/
Darkgray/Olieve/DarkCyan/S.green
Alarm mark color 1: Red
Alarm mark color 2: Orange
Alarm mark color 3: Orange
Alarm mark color 4: Red
Default MV1000 Settings
42