Meas channel > moving average, Meas channel > color, Meas channel > zone, scale – Yokogawa Button Operated MV2000 User Manual
Page 40: Meas channel > bar graph, Meas channel > alarm mark
Setting
Selectable Range or Choices
Default Value
Type
H/L/h/l/R/r/T/t
H
Value
Numeric value
0.000
Relay
On/Off
Off
No.
I01 to I06, S01 to S30
I01
Detect
On/Off
On
Meas channel > Tag, Memory, Delay
Setting
Selectable Range or Choices
Default Value
Meas channel > Range, Alarm
Numeric value (channel number) 1 to 24
1
Tag > Characters
Character string (up to 16 characters)
—
Memory sample
On/Off
On
Alarm delay > Time
Numeric value (1 to 3600) s
10
Meas channel > Moving average
Setting
Selectable Range or Choices
Default Value
First-CH, Last-CH
Numeric value (channel number) 1 to 24
1
On/Off
On/Off
Off
Count
Numeric value (2 to 400)
2
Meas channel > Color
Setting
Selectable Range or Choices
Default Value
Group of channel
001–006/007–012/013–018/019–024
001-006
Color
Red/Green/Blue/B.violet/Brown/Orange/Y.green/
Lightblue/Violet/Gray/Lime/Cyan/Darkblue/Yellow/
Lightgray/Purple/Black/Pink/L.brown/L.green/
Darkgray/Olieve/DarkCyan/S.green
Colors assigned in order to
groups
Red to orange
Meas channel > Zone, Scale
Setting
Selectable Range or Choices
Default Value
First-CH, Last-CH
Numeric value (channel number) 1 to 24
1
Zone > Lower
Numeric value (0 to 95) %
0
Zone > Upper
Numeric value (5 to 100) %
100
Scale > Position
Off/1/2/3/4/5/6
1
Scale > Division
4/5/6/7/8/9/10/11/12/C10
10
Meas channel > Bar graph
Setting
Selectable Range or Choices
Default Value
First-CH, Last-CH
Numeric value (channel number) 1 to 24
1
Base position
Normal/Center/Lower/Upper
Normal
Division
4/5/6/7/8/9/10/11/12
10
Meas channel > Alarm mark
Setting
Selectable Range or Choices
Default Value
First-CH, Last-CH
Numeric value (channel number) 1 to 24
1
On/Off
On/Off
Off
Expand
Numeric value (1 to 99)%
50
Boundary
Numeric value (minimum span value + 1 digit to
maximum span value – 1 digit)
0.0000
Default MV1000 Settings
40
IM MV1000-02E