Using the quick settings function, you can switch quickly to the measurement channel
(measurement range and alarm) and data save configuration screens by pressing
T/DIV.
Procedure
Operate the MV from the Quick settings screen according to the procedure described
below.
• Measurement channels:
Set channels 1 through 4 to the following settings:
Mode: Volt, Range: 2V, Span_L: -2V, Span_U: 2V
• Display-data save settings: Trend/Storage interval: 1min, Save interval: 1h
• Event data save settings: Sample rate: 1s, Mode: Free (mem. sampling started with
START/STOP key), Data length: 1h
List of default MV1000 settings: page 37
Press MENU.
Press the left arrow key.
Press T/DIV.
Set the measurement range
1. Select the channels to configure.
Press
1 for the first channel and 4 for the last channel.
2. Select the
Mode.
Press the
Volt soft key.
3. Select the
Range.
Press the
2V soft key.
4. Enter the span upper and lower limits.
Press the
Input soft key, and select a value with the
up and down arrow keys.