Yokogawa Wireless Temperature Transmitter YTA510 User Manual
Page 28

IM 01C50T03-01E
5-2
5. LIST OF PARAMETERS
E
SET SENSOR2
Set Sensor2
R
E10
SENSOR2 TYPE
Sensor2 sensor type
W
TYPE B, E, J, K, L, N, R, S, T, U, W3, W5,
Pt100, Pt200, Pt500, JPt100, Ni120, Cu,
ohm, mV, Non Connection
E20
SENSOR2 WIRE
Sensor2 wire connection
W
2 WIRE, 3 WIRE
E40
SENSOR2 TEMP
Sensor2 input value
R
Unit specified in E20
E41
SENSOR2 UNIT
Sensor2 engineering unit
W
degC, kelvin, degF
*4
, degR
*4
E50
SNSR2 MATCH
Sensor1 RTD sensor matching
W
DISABLE, ENABLE
E51
SNSR2 R0
Sensor1-specific constant (R0)
W
E52
SNSR2 A
IEC co-efficient
␣
W
E53
SNSR2 B
IEC co-efficient
␦
W
E54
SNSR2 C
IEC co-efficient

W
E55
SNSR2 ALPHA
Callendar-Van-Dusen co-efficient A
W
E56
SNSR2 DELTA
Callendar-Van-Dusen co-efficient B
W
E57
SNSR2 BETA
Callendar-Van-Dusen co-efficient C
W
E60
SELF CHECK
Self-diagnostics
R
Same as A60
F
SET OUTPUT
Set output
R
F10
LRV
Lower range value
W
-5000 to +5000
°
C
F20
URV
Upper range value
W
-5000 to +5000
°
C
F30
AUTO LRV
Automatic setting of lower range value
W
DISABLE, ENABLE(-5000 to +5000
°
C)
F35
AUTO URV
Automatic setting of upper range value
W
DISABLE, ENABLE(-5000 to +5000
°
C)
F40
BURN OUT
Sensor error burn-out output
W
LOW, HIGH, USER mA, USER %, OFF
F41
BURN OUT VAL
Sensor error burn-out value
W
3.6 to 21.6mA (-2.5 to 110%)
F50
TX FAILURE
Hardware error burn-out
R
LOW, HIGH
F60
SELF CHECK
Self-diagnostics
R
Same as A60
G
FORCED OUT
Forced output
R
G10
OUTPUT MODE
Output mode
W
AUTOMATIC MODE, MANUAL MODE mA,
MANUAL MODE %
G20
OUTPUT VALUE
Forced output value
W
3.6 to 21.6mA (-2.5 to 110%)
G60
SELF CHECK
Self-diagnostics
R
Same as A60
H
SET MODE
Set Modes
R
H01
CJC SELECT
CJC Selection
W
Internal CJC, Constant CJC
H02
CNST CJC TMP
Constant for CJC function
W
-5000 to +5000
°
C
H10
REVERSE OUT
Reverse output
W
DISABLE, ENABLE
H20
SNSR BACKUP
Sensor backup
W
DISABLE, ENABLE
H21
RETURN SNS1
Return Sensor1
W
ENABLE, DISABLE
H30
UPLOAD SELCT
Upload parameter select
W
SET PRAM ONLY, ALL PRAM
H40
WRITE PROTCT
Write protect
W
YES, NO
H50
WARNING ENBL
Warning function
W
00000000, 3F1C0000, C0030800, FF1F0800,
00E00108, 3FFC0108, C0E30908, FFFF0908
H60
SELF CHECK
Self-diagnostics
R
Same as A60
I
INFORMATION
Information
R
I10
PV LRL
PV lower range limit
R
I11
PV URL
PV upper range limit
R
I12
PV MIN SPAN
PV minimum span
R
I20
SNSR1 LSL
Sensor1 lower sensor limit
R
I21
SNSR1 USL
Sensor1 upper sensor limit
R
I30
SNSR2 LSL
Sensor2 lower sensor limit
R
I31
SNSR2 USL
Sensor2 upper sensor limit
R
I40
TERM LSL
Terminal lower sensor limit
R
I41
TERM USL
Terminal upper sensor limit
R
I59
WARNING
Warning
R
GOOD/Warning, LRV Low Limited, LRV Upp
Limited, URV Low Limited, URV Upp Limited,
LRV>=URV set, SPAN Below, Sns1 TEMP
Little, Sns1 TEMP Large, Sns2 TEMP Little,
Sns2 TEMP Large, Illegal SV MAP, Illegal TV
MAP, Illegal 4V MAP, Out Reverse Mode,
Out Manual Mode
I60
SELF CHECK
Self-diagnostics
R
Same as A60
—
Pt100
—
3 WIRE
Operation
degC
DISABLE
+100
+3.9083 E-3
-5.7749 E-7
-4.183 E-12
+3.8505 E-3
+1.4998 E0
+1.0862 E-1
GOOD
+0(degC)
+100(degC)
DISABLE
DISABLE
High
110(%)
High
GOOD
AUTOMATIC MODE
Operation
GOOD
Internal CJC
0
DISABLE
DISABLE
DISABLE
SET PRAM ONLY
NO
00000000
GOOD
-200(degC)
+850(degC)
+25(degC)
-200(degC)
+850(degC)
—
-200(degC)
—
+850(degC)
-40(degC)
+85(degC)
GOOD
GOOD
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
NO.
Parameter name
Content
R/W
Remarks
Applicable model
UPLOAD DATA
110 310 320 SET ALL
Data initial value
YTA110 YTA310 YTA320
*1
*2
*3
◆
◆
◆
◆
◆
◆
◆
◆
*
1:
◆
indicates parameters which may be displayed depending on the setting for other parameters.
●
indicates parameters available on the model with optional code /CM1.
*
2: RW: R = Read only, W = Read & Write
*
3: Indicates the parameter selected by H30: UPLOAD SELCT.
SET = SET PRAM ONLY parameters
ALL = ALL PRAM parameters
*
4: degF and degR can be selected only when optional code /D2 is specified.
◆
◆
◆
●
●
●
●
●
●
●
●