beautypg.com

Specifications, 38 specifications, Specifications 38 – Watlow Series 965 User Manual

Page 38

background image

38

WATLOW Series 965 User's Manual

Appendix

Specifications—(1460)
Control Mode
• Microprocessor-based, user selectable control modes
• Single input, dual output
• 2.5Hz Input Sampling Rate
• 1Hz Display Update Rate
• Ramp to set point: 0 to 9999 degrees or units per hour
• Heat and cool auto-tune
Agency Approvals
• UL and C-UL recognized, File #E43684, UL873
• CE approved

89/336/EEC Electromagnetic Compatibility Directive

EN 50081-2: 1994 Emissions
EN 50082-2: 1995 Immunity

73/23/EEC Low -Voltage Directive

EN 61010-1: 1993 Safety

• NEMA 4X

2

, I.P. 65 rating

Operator Interface
• Sealed membrane front panel
• Dual, four-digit red or green displays
• MODE, Up-arrow, Down-arrow, and AUTO/ MANUAL keys
• User selectable screen display
Accuracy
• Calibration accuracy and sensor conformity:

±

0.1% of span,

±

1 LSD @ 77

°

F

±

5

°

F (25

°

C

±

3

°

C) ambient and rated line

voltage

• Accuracy span: 1000

°

F (540

°

C) minimum

• Temperature stability:

±

0.2

°

F/

°

F (

±

0.2

°

C/

°

C) rise in ambient

maximum

• Voltage stability:

±

0.01% of span per percent of rated line

voltage

Sensors/Inputs
• Thermocouple, grounded or ungrounded sensors
• RTD 2- or 3-wire, platinum, 100

@ 0

°

C calibration to DIN

curve (0.00385

/

/

°

C) or JIS curve (0.003916

/

/

°

C); user

selectable

• Process, 4-20mA @ 5

, or 0-5V

Î

(dc) @ 10k

input

impedance

• Sensor break protection de-energizes control output to

protect system or selectable bumpless transfer to manual
operation

°

F or

°

C or process units display, user selectable

Input Range
Specified temperature ranges represent the controller’s

operational span.

• Thermocouple

Type J

32

to

1382

°

F

(0

to

750

°

C)

Type K

-328

to

2282

°

F

(-200

to

1250

°

C)

Type N

32

to

2282

°

F

(0

to

1250

°

C)

Type S

32

to

2642

°

F

(0

to

1450

°

C)

Type T

-328

to

662

°

F

(-200

to

350

°

C)

• RTD Resolution (DIN or JIS)

1

°

-328

to

1292

°

F

(-200

to

700

°

C)

0.1

°

-199.9

to

999.9

°

F

(-128.8

to

537.7

°

C)

• Process

4-20mA @ 5

, or -999 to 9999 units

0-5V

Î

(dc) @ 10k

, or -999 to 9999 units

Output 1 (Heating or Cooling)
• Electromechanical relay

1

, Form C, 5A @ 120/240V~ (ac)

maximum, without contact suppression, rated resistive load,
5A @ 30V

Î

(dc)

3

.

• Switched dc signal provides a non-isolated minimum turn on

voltage of 3V

Î

(dc) into a minimum 500

load; maximum on

voltage not greater than 12V

Î

(dc) into an infinite load.

• 4-20mA reverse or direct acting, non-isolated 0 to 800

load.

• Solid-state relay

3

, Form A, 0.5A @ 24V~ (ac) min., 264V~

(ac) max., opto-isolated burst fire switched, without contact
suppression. Off-state output impedance is 31M

.

Output 2 (Heat, Cool or Alarm)
• Electromechanical relay

1

, Form C, 5A @ 120/240V~ (ac)

maximum, without contact suppression, rated resistive load,
5A @ 30V

Î

(dc)

3

.

• Switched dc signal provides a non-isolated minimum turn on

voltage of 3V

Î

(dc) into a minimum 500

load; maximum

on voltage not greater than 12V

Î

(dc) into an infinite load.

• Solid-state relay

3

, Form A, 0.5A @ 24V~ (ac) min., 264V~

(ac) max., opto-isolated burst fire switched, without contact
suppression. Off-state output impedance is 31M

.

• Alarm output can be latching or non-latching, and process or

deviation with separate high and low values. Alarm silencing
(inhibit) on power up.

Output Configurations
• Output 1
User selectable as: on/off: P, PI, PD, PID, heat or cool action
• Adjustable switching differential: 1 to 99

°

F (1 to 55

°

C)

• Proportional band: 0 (off) or 1 to 999

°

F (0 to 555

°

C) or 0.0 to

999.9 units

Integral: 0 (off) or 0.1 to 99.9 minutes per repeat
Reset: 0 (off) or 0.01 to 9.99 repeats per minute
Rate/derivative: 0 (off) or 0.01 to 9.99 minutes
Cycle time: 0.1 to 999.9 seconds
• Output 2
User selectable as: Control with action opposite that of Output

1 (heating or cooling)

• Process or deviation alarm with flashing alarm message
• Process or deviation alarm without alarm message
• Alarm with separate high and low set points
• Hysteresis: 1 to 9999

°

or units switching differential

Line Voltage/Power
• 100-240V~ (ac), +10%, -15%; (85-264V~ [ac]) 50/60Hz,

±

5%

•12-24V

ı

(ac/dc), +10%, -15%; (10-26V

ı

[ac/dc]) 50/60Hz,

±

5%

• Fused internally (factory replaceable only) Slo-Blo® type

(time-lag):

1A, 250V for high voltage versions
2A, 250V for low voltage versions

• Power consumption 5VA maximum
• Data retention upon power failure via non-volatile memory
Operating Environment
• 32 to 149

°

F (0 to 65

°

C)

• 0 to 90% RH, non-condensing
Storage Temperature
• -40

°

to 185

°

F (-40

°

to 85

°

C)

Terminals
• #6 compression universal head screw terminals, accepts 20-

14 gauge wire

Controller Weight
• 0.4 lb

(0.2 kg)

Shipping Weight
• 0.75 lb (0.34 kg)
Dimensions
• Compact 1⁄16 DIN size and NEMA 4X

2

, (I.P. 65) front panel

make the Series 965 easy to apply and maintain in a wide
variety of applications. Unique mounting bezel, gasket and
collar make installation a snap.

Overall

Height:

2.1 inches

(55 mm)

Width:

2.1 inches

(55 mm)

Depth:

4.7 inches

(120 mm)

Bezel

Height:

2.1 inches

(55 mm)

Width:

2.1 inches

(55 mm)

Depth:

0.6 inches

(15 mm)

Chassis Height:

1.8 inches

(45 mm)

Width:

1.8 inches

(45 mm)

Depth:

4.1 inches

(105 mm)

1

Electromechanical relays warranted for 100,000 closures

only. Solid-state switching devices recommended for
applications requiring fast cycle times or extended service
life.

2

To effect NEMA 4X (I.P. 65) rating requires a minimum

mounting panel thickness of 0.06inch (1.5 mm) and surface
finish not rougher than 0.000032 inch (0.000812 mm).

3

Switching inductive loads (relay coils, etc.) requires using an

RC suppressor.

Specifications