beautypg.com

Series 142 – Watlow Series 142 Retrofit User Manual

Page 29

background image

Series 142

Series 142

Line

Voltage

Input

Temp Range

Control Mode

Action

Output

Set Point

Mounting

Retrofit

See Notes

Below

142A-3669-2200

230 VAC

E t/c

383°F

High limit

Manual Reset

3A Relay

Fixed

Potted

LF E4SU 0383 AAAA A

6, 8

142A-3669-2200

230 VAC

E t/c

110°C

High limit

Manual Reset

3A Relay

Fixed

Potted

LF E4TU 0110 AAAA A

6, 8

142A-3669-2300

230 VAC

E t/c

383°F

High limit

Automatic Reset

3A Relay

Fixed

Potted

LF E4SW 0383 AAAA A

6, 8

142A-3669-2300

230 VAC

E t/c

110°C

High limit

Automatic Reset

3A Relay

Fixed

Potted

LF E4TW 0110 AAAA A

6, 8

142A-3669-2400

230 VAC

E t/c

383°F

On/Off

Heat

3A Relay

Fixed

Potted

CF E4SH 0383 AAAA A

6, 8

142A-3669-2400

230 VAC

E t/c

110°C

On/Off

Heat

3A Relay

Fixed

Potted

CF E4TH 0110 AAAA A

6, 8

142A-3670-1200

120 VAC

E t/c

423°F

High limit

Manual Reset

3A Relay

Fixed

Potted

LF C4SU 0423 AAAA A

6, 8

142A-3670-1200

120 VAC

E t/c

150°C

High limit

Manual Reset

3A Relay

Fixed

Potted

LF C4TU 0150 AAAA A

6, 8

142A-3670-1300

120 VAC

E t/c

423°F

High limit

Automatic Reset

3A Relay

Fixed

Potted

LF C4SW 0423 AAAA A

6, 8

142A-3670-1300

120 VAC

E t/c

150°C

High limit

Automatic Reset

3A Relay

Fixed

Potted

LF C4TW 0150 AAAA A

6, 8

142A-3670-1400

120 VAC

E t/c

423°F

On/Off

Heat

3A Relay

Fixed

Potted

CF C4SH 0423 AAAA A

6, 8

142A-3670-1400

120 VAC

E t/c

150°C

On/Off

Heat

3A Relay

Fixed

Potted

CF C4TH 0150 AAAA A

6, 8

142A-3670-2200

230 VAC

E t/c

423°F

High limit

Manual Reset

3A Relay

Fixed

Potted

LF E4SU 0423 AAAA A

6, 8

142A-3670-2200

230 VAC

E t/c

150°C

High limit

Manual Reset

3A Relay

Fixed

Potted

LF E4TU 0150 AAAA A

6, 8

142A-3670-2300

230 VAC

E t/c

423°F

High limit

Automatic Reset

3A Relay

Fixed

Potted

LF E4SW 0423 AAAA A

6, 8

142A-3670-2300

230 VAC

E t/c

150°C

High limit

Automatic Reset

3A Relay

Fixed

Potted

LF E4TW 0150 AAAA A

6, 8

142A-3670-2400

230 VAC

E t/c

423°F

On/Off

Heat

3A Relay

Fixed

Potted

CF E4SH 0423 AAAA A

6, 8

142A-3670-2400

230 VAC

E t/c

150°C

On/Off

Heat

3A Relay

Fixed

Potted

CF E4TH 0150 AAAA A

6, 8

142A-3671-1200

120 VAC

K t/c

550°F

High limit

Manual Reset

3A Relay

Fixed

Potted

LF C4KU 0550 AAAA A

6, 8

142A-3671-1200

120 VAC

K t/c

288°C

High limit

Manual Reset

3A Relay

Fixed

Potted

LF C4LU 0288 AAAA A

6, 8

142A-3671-1300

120 VAC

K t/c

550°F

High limit

Automatic Reset

3A Relay

Fixed

Potted

LF C4KW 0550 AAAA A

6, 8

142A-3671-1300

120 VAC

K t/c

288°C

High limit

Automatic Reset

3A Relay

Fixed

Potted

LF C4LW 0288 AAAA A

6, 8

142A-3671-1400

120 VAC

K t/c

550°F

On/Off

Heat

3A Relay

Fixed

Potted

CF C4KH 0550 AAAA A

6, 8

142A-3671-1400

120 VAC

K t/c

288°C

On/Off

Heat

3A Relay

Fixed

Potted

CF C4LH 0288 AAAA A

6, 8

142A-3671-2200

230 VAC

K t/c

550°F

High limit

Manual Reset

3A Relay

Fixed

Potted

LF E4KU 0550 AAAA A

6, 8

142A-3671-2200

230 VAC

K t/c

288°C

High limit

Manual Reset

3A Relay

Fixed

Potted

LF E4LU 0288 AAAA A

6, 8

142A-3671-2300

230 VAC

K t/c

550°F

High limit

Automatic Reset

3A Relay

Fixed

Potted

LF E4KW 0550 AAAA A

6, 8

142A-3671-2300

230 VAC

K t/c

288°C

High limit

Automatic Reset

3A Relay

Fixed

Potted

LF E4LW 0288 AAAA A

6, 8

142A-3671-2400

230 VAC

K t/c

550°F

On/Off

Heat

3A Relay

Fixed

Potted

CF E4KH 0550 AAAA A

6, 8

142A-3671-2400

230 VAC

K t/c

288°C

On/Off

Heat

3A Relay

Fixed

Potted

CF E4LH 0288 AAAA A

6, 8

142A-3672-1200

120 VAC

J t/c

185°F

High limit

Manual Reset

3A Relay

Fixed

Potted

LF C4HU 0185 AAAA A

6, 8

142A-3672-1200

120 VAC

J t/c

85°C

High limit

Manual Reset

3A Relay

Fixed

Potted

LF C4JU 0085 AAAA A

6, 8

142A-3672-1300

120 VAC

J t/c

185°F

High limit

Automatic Reset

3A Relay

Fixed

Potted

LF C4HW 0185 AAAA A

6, 8

142A-3672-1300

120 VAC

J t/c

85°C

High limit

Automatic Reset

3A Relay

Fixed

Potted

LF C4JW 0085 AAAA A

6, 8

142A-3672-1400

120 VAC

J t/c

185°F

On/Off

Heat

3A Relay

Fixed

Potted

CF C4HH 0185 AAAA A

6, 8

142A-3672-1400

120 VAC

J t/c

85°C

On/Off

Heat

3A Relay

Fixed

Potted

CF C4JH 0085 AAAA A

6, 8

142A-3672-2200

230 VAC

J t/c

185°F

High limit

Manual Reset

3A Relay

Fixed

Potted

LF E4HU 0185 AAAA A

6, 8

142A-3672-2200

230 VAC

J t/c

85°C

High limit

Manual Reset

3A Relay

Fixed

Potted

LF E4JU 0085 AAAA A

6, 8

142A-3672-2300

230 VAC

J t/c

185°F

High limit

Automatic Reset

3A Relay

Fixed

Potted

LF E4HW 0185 AAAA A

6, 8

142A-3672-2300

230 VAC

J t/c

85°C

High limit

Automatic Reset

3A Relay

Fixed

Potted

LF E4JW 0085 AAAA A

6, 8

142A-3672-2400

230 VAC

J t/c

185°F

On/Off

Heat

3A Relay

Fixed

Potted

CF E4HH 0185 AAAA A

6, 8

Watlow Controls

1/31/2005

Page 24