Series 142 – Watlow Series 142 Retrofit User Manual
Page 22
![background image](/manuals/359168/22/background.png)
Series 142
Series 142
Line
Voltage
Input
Temp Range
Control Mode
Action
Output
Set Point
Mounting
Retrofit
See Notes
Below
142A-3645-2200
230 VAC
K t/c
871°C
High limit
Manual Reset
3A Relay
Fixed
Potted
LF E4LU 0871 AAAA A
6, 8
142A-3645-2300
230 VAC
K t/c
1600°F
High limit
Automatic Reset
3A Relay
Fixed
Potted
LF E4KW 1600 AAAA A
6, 8
142A-3645-2300
230 VAC
K t/c
871°C
High limit
Automatic Reset
3A Relay
Fixed
Potted
LF E4LW 0871 AAAA A
6, 8
142A-3645-2400
230 VAC
K t/c
1600°F
On/Off
Heat
3A Relay
Fixed
Potted
CF E4KH 1600 AAAA A
6, 8
142A-3645-2400
230 VAC
K t/c
871°C
On/Off
Heat
3A Relay
Fixed
Potted
CF E4LH 0871 AAAA A
6, 8
142A-3646-1200
120 VAC
K t/c
1650°F
High limit
Manual Reset
3A Relay
Fixed
Potted
LF C4KU 1650 AAAA A
6, 8
142A-3646-1200
120 VAC
K t/c
899°C
High limit
Manual Reset
3A Relay
Fixed
Potted
LF C4LU 0899 AAAA A
6, 8
142A-3646-1300
120 VAC
K t/c
1650°F
High limit
Automatic Reset
3A Relay
Fixed
Potted
LF C4KW 1650 AAAA A
6, 8
142A-3646-1300
120 VAC
K t/c
899°C
High limit
Automatic Reset
3A Relay
Fixed
Potted
LF C4LW 0899 AAAA A
6, 8
142A-3646-1400
120 VAC
K t/c
1650°F
On/Off
Heat
3A Relay
Fixed
Potted
CF C4KH 1650 AAAA A
6, 8
142A-3646-1400
120 VAC
K t/c
899°C
On/Off
Heat
3A Relay
Fixed
Potted
CF C4LH 0899 AAAA A
6, 8
142A-3646-2200
230 VAC
K t/c
1650°F
High limit
Manual Reset
3A Relay
Fixed
Potted
LF E4KU 1650 AAAA A
6, 8
142A-3646-2200
230 VAC
K t/c
899°C
High limit
Manual Reset
3A Relay
Fixed
Potted
LF E4LU 0899 AAAA A
6, 8
142A-3646-2300
230 VAC
K t/c
1650°F
High limit
Automatic Reset
3A Relay
Fixed
Potted
LF E4KW 1650 AAAA A
6, 8
142A-3646-2300
230 VAC
K t/c
899°C
High limit
Automatic Reset
3A Relay
Fixed
Potted
LF E4LW 0899 AAAA A
6, 8
142A-3646-2400
230 VAC
K t/c
1650°F
On/Off
Heat
3A Relay
Fixed
Potted
CF E4KH 1650 AAAA A
6, 8
142A-3646-2400
230 VAC
K t/c
899°C
On/Off
Heat
3A Relay
Fixed
Potted
CF E4LH 0899 AAAA A
6, 8
142A-3647-1200
120 VAC
K t/c
1700°F
High limit
Manual Reset
3A Relay
Fixed
Potted
LF C4KU 1700 AAAA A
6, 8
142A-3647-1200
120 VAC
K t/c
927°C
High limit
Manual Reset
3A Relay
Fixed
Potted
LF C4LU 0927 AAAA A
6, 8
142A-3647-1300
120 VAC
K t/c
1700°F
High limit
Automatic Reset
3A Relay
Fixed
Potted
LF C4KW 1700 AAAA A
6, 8
142A-3647-1300
120 VAC
K t/c
927°C
High limit
Automatic Reset
3A Relay
Fixed
Potted
LF C4LW 0927 AAAA A
6, 8
142A-3647-1400
120 VAC
K t/c
1700°F
On/Off
Heat
3A Relay
Fixed
Potted
CF C4KH 1700 AAAA A
6, 8
142A-3647-1400
120 VAC
K t/c
927°C
On/Off
Heat
3A Relay
Fixed
Potted
CF C4LH 0927 AAAA A
6, 8
142A-3647-2200
230 VAC
K t/c
1700°F
High limit
Manual Reset
3A Relay
Fixed
Potted
LF E4KU 1700 AAAA A
6, 8
142A-3647-2200
230 VAC
K t/c
927°C
High limit
Manual Reset
3A Relay
Fixed
Potted
LF E4LU 0927 AAAA A
6, 8
142A-3647-2300
230 VAC
K t/c
1700°F
High limit
Automatic Reset
3A Relay
Fixed
Potted
LF E4KW 1700 AAAA A
6, 8
142A-3647-2300
230 VAC
K t/c
927°C
High limit
Automatic Reset
3A Relay
Fixed
Potted
LF E4LW 0927 AAAA A
6, 8
142A-3647-2400
230 VAC
K t/c
1700°F
On/Off
Heat
3A Relay
Fixed
Potted
CF E4KH 1700 AAAA A
6, 8
142A-3647-2400
230 VAC
K t/c
927°C
On/Off
Heat
3A Relay
Fixed
Potted
CF E4LH 0927 AAAA A
6, 8
142A-3648-1200
120 VAC
K t/c
1750°F
High limit
Manual Reset
3A Relay
Fixed
Potted
LF C4KU 1750 AAAA A
6, 8
142A-3648-1200
120 VAC
K t/c
954°C
High limit
Manual Reset
3A Relay
Fixed
Potted
LF C4LU 0954 AAAA A
6, 8
142A-3648-1300
120 VAC
K t/c
1750°F
High limit
Automatic Reset
3A Relay
Fixed
Potted
LF C4KW 1750 AAAA A
6, 8
142A-3648-1300
120 VAC
K t/c
954°C
High limit
Automatic Reset
3A Relay
Fixed
Potted
LF C4LW 0954 AAAA A
6, 8
142A-3648-1400
120 VAC
K t/c
1750°F
On/Off
Heat
3A Relay
Fixed
Potted
CF C4KH 1750 AAAA A
6, 8
142A-3648-1400
120 VAC
K t/c
954°C
On/Off
Heat
3A Relay
Fixed
Potted
CF C4LH 0954 AAAA A
6, 8
142A-3648-2200
230 VAC
K t/c
1750°F
High limit
Manual Reset
3A Relay
Fixed
Potted
LF E4KU 1750 AAAA A
6, 8
142A-3648-2200
230 VAC
K t/c
954°C
High limit
Manual Reset
3A Relay
Fixed
Potted
LF E4LU 0954 AAAA A
6, 8
142A-3648-2300
230 VAC
K t/c
1750°F
High limit
Automatic Reset
3A Relay
Fixed
Potted
LF E4KW 1750 AAAA A
6, 8
142A-3648-2300
230 VAC
K t/c
954°C
High limit
Automatic Reset
3A Relay
Fixed
Potted
LF E4LW 0954 AAAA A
6, 8
142A-3648-2400
230 VAC
K t/c
1750°F
On/Off
Heat
3A Relay
Fixed
Potted
CF E4KH 1750 AAAA A
6, 8
142A-3648-2400
230 VAC
K t/c
954°C
On/Off
Heat
3A Relay
Fixed
Potted
CF E4LH 0954 AAAA A
6, 8
Watlow Controls
1/31/2005
Page 17