Proface APL3000B - Node Box PC User Manual
Page 36
Chapter 2 Specifications
2-13
Switch
No.
Description
ON
OFF
Notes
1
Used for the system.
Reserved
Reserved
Factory Settings: ON
2
Used for the system.
Reserved
Reserved
Factory Settings: OFF
3
Used for the system.
Reserved
Reserved
Factory Settings: OFF
4
Cancellation function of pushing
two points on the touch panel
*1
.
*1
When two points are pushed, it is considered that middle point between the two points is
touched according to the nature of the analog resistive touch panel.
When the switch, etc. is set on the middle point, it will be enabled and may operate.
To prevent such a switch from malfunction in case of pushing two points, turn ON the SW No.4
in advance, then the middle point will be disabled to be touched.
Enabled
Disabled
Factory Settings: OFF
The middle point is not
considered to be touched
when the SW is Enabled. It is
considered to be touched
when the SW is Disabled.
5
Used for the system.
Reserved
Reserved
Factory Settings: OFF
6
Changes Reset SW mode.
Power
button
Reset SW
Factory Settings: OFF
7
Used for the system.
Reserved
Reserved
Factory Settings: OFF
8
Changes COM2 (RI <---> +5V).
(enabled only when RS-232C
mode)
+5V Output
RI
Factory Settings: OFF
9
Changes a Master/Slave setting for
Primary CF card Interface.
Slave
Master
The factory settings depend
on your selected built-in
accessory.
10
Used for the system.
Reserved
Reserved
Factory Settings: OFF
Table 1) System Set Switches
Switch
Number
Description
ON
OFF
RS-232C
RS-422
RS-485
1
Changes COM2's
communication
method
RS-232C
RS-422 / RS-485 ON
OFF
*1
OFF
2
Changes COM2's
communication
method
RS-422 / RS-485 RS-232C
OFF
ON
ON
3
Changes COM2's
communication
method
RS-422 / RS-485 RS-232C
OFF
ON
ON