Attachment method – Proface GP4600R - 12.1 Standard HMIs with Rear Mounting Options" User Manual
Page 6

6
RS-422
Unit's Connector
: XM3B-0942-132L
Recommended Connector
: XM2A-0901
Recommended Cover
: XM2S-0913
Jack Screw
: XM2Z-0073
Stacking Metal Fittings require #4-40 inch screw.
Attachment Method
• For the GP-4200 series, attach the unit to the panel.
Attaching the Unit directly to the Display
When attaching the unit on the rear side of the Display, among the 4 screws shown in the diagram
below, use 2 horizontally positioned or 2 vertically positioned screws to attach the unit. If the
Display already has an attachment, it may restrict the direction in which you can place the unit.
Pin Arrangement
Pin #
RS-422
Signal Name
Direction
Meaning
1
TRMRX
-
Termination
(Receive side: 100
Ω)
2
RDA
Input
Receive Data A(+)
3
SDA
Output
Send Data A (+)
4
NC
-
No connection
5
SG
-
Signal Ground
6
VCC
-
+5V
±
5% output 0.05A
*1
*1
The VCC output for Pin #6 is not protected against overcurrent. To prevent
damage or unit malfunctions, use only the rated current.
7
RDB
Input
Receive Data B(-)
8
SDB
Output
Send Data B(-)
9
TRMTX
-
Termination (Send side: 100
Ω)
Shell
FG
-
Frame Ground
5
1
6
9
75[2.95]
75[2.95]
EXT*
- GP4500R - 10.4 Standard HMIs with Rear Mounting Options" GP4400R - 7.5 Standard HMI with Rear Mounting Options" GP4300R - 5.7 Standard HMI with Rear Mount" GP4300M - 5.7 Modular HMI" GP4200M - 3.5 Modular HMI" GP4500 - 10.4 W Model HMI" GP4400 - 7.0 W Model HMI" GP4300 - 5.7 W Model HMI" GP4200 - 3.5 W Model HMI" GP4600 - 12.1 Standard HMIs" GP4500 - 10.4 Standard HMIs" GP4400 - 7.5 Standard HMI" GP4300 - 5.7 Standard HMI" GP4200 - 3.5 Standard HMIs"