Installation, operation and maintenance, Danger – Proface GP4600R - 12.1 Standard HMIs with Rear Mounting Options" User Manual
Page 4
4/7
Installation, Operation and Maintenance
Make sure you follow all the recommendations in the GP4000 Series
Installation Guide and additionally those listed below.
DANGER
POTENTIAL FOR EXPLOSION
•
Confirm that the location is free from explosively hazardous gases or
dust before connecting or disconnecting equipment, replacing or
wiring modules.
•
The ambient temperature in protective enclosure must not exceed
50°C or 55°C (refer to marking).
•
Confirm each interface (COM1, COM2, LAN), field wiring terminal
blocks and the SD Card / Battery Cover have been securely locked.
•
Confirm USB cables are attached with its appropriate clamp.
•
Modules must be installed in a protective enclosure that provides at
least the following degree of protection:
- IP54 for atmosphere with gas
- IP6x for atmosphere with dust
•
Do not open the protective enclosure while the system is powered up.
•
Confirm that the power supply has been turned OFF before
disconnecting, replacing or wiring modules.
•
Ensure that the FG (Functional Ground) on the power supply is
properly connected to ground.
•
Use only screw fasteners suitable for installations in explosive
atmospheres.
•
Do not use damaged equipment.
•
Use Touch Pen CA7-TPPEN/ALL-01 on all GP4000 Series used in
zone 2 and zone 22 areas.
Failure to follow these instructions will result in death or serious injury.
- GP4500R - 10.4 Standard HMIs with Rear Mounting Options" GP4400R - 7.5 Standard HMI with Rear Mounting Options" GP4300R - 5.7 Standard HMI with Rear Mount" GP4300M - 5.7 Modular HMI" GP4200M - 3.5 Modular HMI" GP4500 - 10.4 W Model HMI" GP4400 - 7.0 W Model HMI" GP4300 - 5.7 W Model HMI" GP4200 - 3.5 W Model HMI" GP4600 - 12.1 Standard HMIs" GP4500 - 10.4 Standard HMIs" GP4400 - 7.5 Standard HMI" GP4300 - 5.7 Standard HMI" GP4200 - 3.5 Standard HMIs"