beautypg.com

Maple Systems OMI5100A-CE User Manual

Page 14

background image

14

OMI5000 Series Installation Guide

1010-1013 Rev 01 www.maplesystems.com

Maintenance

Figure 6: DIP switch positions (power must be cycled on the OMI to enable the DIP
switch mode).

SW1

SW2

SW3

SW4

Mode

ON

OFF

OFF

OFF

Touchscreen Calibration mode

OFF

ON

OFF

OFF

Reserved

OFF

OFF

ON

OFF

Force into Boot Loader mode

OFF

OFF

OFF

ON

Reserved

OFF

OFF

OFF

OFF

Normal operation


Touchscreen Calibration mode: This mode allows you to recalibrate
the touchscreen.

Boot Loader mode: This mode forces the OMI to not execute the
project. This mode is used when replacing or reinstalling the operating
system. Contact Maple Systems for more information.

Normal Operation: All DIP switches must be in the OFF position for
normal operation.

Fusing Requirements

If the display does not come on within two seconds of power up, remove
power. An internal fuse will prevent damage if the polarity of the DC
power is incorrect. Check wiring to insure proper connections and try to
power up again.

Serial Port Connections

The diagrams below indicate the proper pin connections for the serial
ports of the OMIs.