Mounting and Installation

27

Metreau Entry Communicators

Ferrite Installation (Required)

The CB-MET-ECOMS comes with a Cat5 Suppression Ferrite that must be clipped around the Ethernet
cable, inside the back box (no tools required).

1.

Release the latch to open the plastic enclosure.

2.

Insert the Cat5 cable and close the enclosure.

Installing the Metreau Entry Communicator

The Metreau Entry Communicator clips onto the front of the Surface Mount Box via the four mounting
tabs (two on each side), and the mounting clip at the bottom center of the box (FIG. 24):

FIG. 23

Installing the CAT5 Suppression Ferrite

1

2

3

(complete)

When positioning the Ferrite clip inside the back box, place the bottom of the clip flat
against the back inside surface of the back box, to allow sufficient room for the
Metreau Entry Communicator unit.

FIG. 24

Installing the Metreau Entry Communicator unit on the Surface Mount Box

Metreau Entry Communicator

Surface Mount Box

bottom security tab

Cables enter through the
Conduit Routing Hole
in the back panel