beautypg.com

Time/date – Airlink CDMA/1x User Manual

Page 82

background image

76

Raven CDMA User Guide for Verizon, version 2.23

Time/Date

Time and Date in the

Raven

is set to UTC (Coordinated Universal Time). Time is

expressed in 24-hour format, i.e. 13:23:57 would be 1:23pm. You can set time and
date manually or you can have it set automatically with a regular query to an Inter-
net time server (such as time.nist.gov) using SNTP (Simple Network Time Proto-
col).

*TELNETTIMEOUT=n

n=minutes

Telnet port inactivity time out.

By default, this value is set to close the AT telnet con-
nection if no data is received for 2 minutes.

*TPORT=p

p=0-65535

Sets or queries the port used for the AT Telnet server. If 0
is specified, the AT Telnet server will be disabled. The
default value is 2332.

TABLE 10.

Time and Date

Command

Parameters

Details

*DATE=[mm/dd/
yyyy
],[hh:mm:ss]

mm/dd/yyyy =

month, day, year

hh:mm:ss =
time in 24-hour
notation

Sets and queries the clock in the unit. Either the date and
time can be specified, or simply one of the two can be
specified in which case the unspecified value will remain
unchanged. The date and time are always specified 24-
hour notation.

*SNTP=n

n=0 or 1

Enables daily SNTP update of the system time.

0 : Off

1 : On

*SNTPADDR=
[d.d.d.d][name]

d.d.d.d=IP

name=domain
name

SNTP Server IP address, or fully-qualified domain
name, to use if *SNTP=1.

Note: If blank, time.nist.gov is used.

*SNTPQUERY?

none

The current SNTP time and date.

TABLE 9.

Telnet

Command Parameters