Troubleshooting, Caution, Step 1 short circuit – Lincoln Electric IM10149 POWER WAVE ADVANCED MODULE User Manual

Page 35: Ac/stt, Functional test preparation

background image

E-2

TROUBLESHOOTING

E-2

POWER WAVE® ADVANCED MODULE

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

Observe all Safety Guidelines detailed throughout this manual

SteP 1 SHort CIrCuIt

•ConnecttheAdvancedModuletoaPowerWaveS350/S500orothercompatiblemachine.

Thistestassumesthehostpowersourcehasbeencalibrated.

•VerifythelatestsoftwareisloadedinthePowerWavemachine.

UpdatedSTTtestmode(208)
(CanbeverifiedbyconfirmingDCNegativetestmode(213)andACtestmode(219)arepresent.

•ShorttheWorktotheElectrodeontheAdvancedModule.

(TotalCableLength≤ 10ft.)

•EnabletestmodesontheUIoftheWireFeeder.

SeeWireFeederinstructionmanual(set-upmenuselectionP.99).

•Selecttestmode208(STT

®

TestMode).

•Enabletheoutput.

Pullingthetrigger,orturnthetrimknobclockwise.
note: Anaudible“buzz”fromtheAdvancedModuleisnormal.

•ReadVoltagefeedbackdisplayedontheWireFeederDisplay.

aC/Stt

®

FunCtIonaL teSt PreParatIon

Voltage

<2V

10-15VAC

>40V

Indication / Possible Cause

aC Switch Shorted:

•Faulty or disconnected Differential I/O control signal (grey cable located at rear of

module).

Verify cable connections (including those internal to the module and host power
source).

•ACSwitchShorted(typically accompanied by error 99).

Disconnect and perform aC Switch PCB test.

normal operation

aC Switch open:

•Looseoropenconnection.

Verifyweldcableconnections(both internal and external to the module – includ-
ing quick connections)
.

•ACSwitchnotclosing(may be accompanied by error 99).

VerifystatusoftheACSwitchboardviathe“onboard”diagnosticLED’s.