Operation – Lincoln Electric IM10149 POWER WAVE ADVANCED MODULE User Manual

Page 32

background image

B-4

OPERATION

B-4

POWER WAVE

®

ADVANCED MODULE

FIGURE B.2

1

2

3

4

5

6

CASE BACK DESCRIPTIONS

(See Figure B.2)

1. DIFFERENTIAL I/O PIGTAIL – Connects directly to the Differential I/O output receptacle on the rear of the

power source.

2. ARCLINK

®

PIGTAIL – Connects directly to the ArcLink

®

Out receptacle on the rear of the power source.

3. DIFFERENTIAL I/O (SYNC TANDEM) OUTPUT – Supports Synchronized Tandem MIG Welding with other

compatible power sources.

4. ARCLINK

®

(OUT) – Provides an ArcLink

®

pass through connection for all compatible ArcLink

®

wire feeders.

5. GAS INPUT – Provides a solenoid controlled gas feed to TIG ELECTRODE on Case Front.

6. WATER COOLER PASS THROUGH – Provides a channel to conceal and protect the power and control leads

for the optional integrally mounted CE Water Cooler.