Upgrading Modero Firmware

81

7" Modero Widescreen Touch Panels

11. Click the Reboot Device checkbox. This causes the touch panel to reboot after the firmware

update process is complete. The reboot of the panel can take up 30 seconds after the firmware

process has finished.

12. Click Send to begin the transfer. The file transfer progress is indicated on the bottom-right of

the dialog (B in FIG. 72).

13. As the panel is rebooting, temporarily unplug the USB connector on the panel until the panel

has completely restarted.

14. Once the first panel page has been displayed, reconnect the USB connector to the panel.

15. Right-click the associated System number and select Refresh System. This causes a refresh of

all project systems, establishes a new connection to the Master, and populates the System list

with devices on your particular system.

16. Confirm the panel has been properly updated to the correct firmware version.

Upgrading the Modero Firmware via Ethernet (IP Address)

Before beginning with this section, verify that your panel is powered and connected to the NetLinx

Master through an Ethernet connection (direct or wireless).

Step 1: Prepare the Master for communication via an IP

1.

Obtain the IP Address of the NetLinx Master from your System Administrator. If you do not

have an IP Address for the Master, refer to your particular Master’s instruction manual for

more information on obtaining this IP Address using NetLinx Studio 2.3 or higher.

From the Online Tree tab of the Workspace window, select the NetLinx Master.

Follow steps outlined in either the Obtaining or Assigning the Master’s IP Address

sections from your particular NetLinx Master instruction manual to use an address.

Note the IP Address and Gateway information.

2.

Launch NetLinx Studio 2.3 (default location is Start > Programs > AMX Control Disc >

NetLinx Studio > NetLinx Studio 2.3).

3.

Select Settings > Master Communication Settings, from the Main menu to open the Master

Communication Settings dialog (FIG. 73).

4.

Click the Communications Settings button to open the Communications Settings dialog.

5.

Click on the NetLinx Master radio button (from the Platform Selection section) to indicate

that you are working with a NetLinx Master (such as the NXC-ME260/64 or NI-Series of

Integrated Controllers).

6.

Click on the Authentication Required radio box (if the Master is secured) and then enter a

username and password.

7.

Click on the TCP/IP radio button (from the Transport Connection Option section) to indicate

you are connecting to the Master through an IP Address.

8.

Click the Edit Settings button (on the Communications Settings dialog) to open the TCP/IP

Settings dialog (FIG. 73).