Configuring Communication

66

7" Modero Widescreen Touch Panels

Step 2: Choose a Master Connection Mode Setting

There are three Ethernet MODE settings used in the Master Connection section of the System

Connection page. URL is the most common method.

Master Connection MODE options:

Step 3: Configure an Ethernet Connection Type

Before beginning:

1.

Verify the panel has been configured to communicate either through an Ethernet cable

(connected from either the panel to a valid Ethernet Hub) or to a wirelessly to the Wireless

Access Point (WAP).

2.

Verify that the NetLinx Master is receiving power and is communicating via an Ethernet

connection with the PC running NetLinx Studio.

3.

Connect the terminal end of the PSN power cable to the 12 VDC power connector on the

rear/side of the touch panel.

4.

Verify the green Ethernet LED (from the rear Ethernet port on the Master) is illuminated

(indicating a proper connection).

5.

Verify the yellow LED (from the rear Ethernet port on the Master) is blinking (indicating

communication).

6.

After the panel powers-up, press and hold the grey Front Setup Access button (for 3 seconds)

to proceed to the Setup page.

7.

Select Protected Setup > System Connection (located on the lower-left) to open the System

Connection page (FIG. 61).

URL (Uniform Resource Locator) is the address that defines the route to a file on the Web or

any other Internet facility.
In this system, the panel acts as a "Client" and the Master acts as a Server (in that Clients attach
to it).

LISTEN sets the Modero panel to "listen" for broadcasts from the Master (using the panel IP from

its URL list). In this system, the panel acts as a "Server" (in that Clients attach to it) and the
Master acts as a "Client".

AUTO is used to instruct the Modero to search for a Master that uses the same System Number

(assigned within the Master Connection section) and resides on the same Subnet as itself. In this
case, the Master has its UDP feature enabled.
This UDP (User Datagram Protocol) is a protocol within the TCP/IP protocol suite that is used in
place of TCP when a reliable delivery is not required.
This UDP enabling is done through a Telnet session on the Master. Refer to the particular NetLinx
Master manual for more detailed information.

When using Ethernet as your communication method, the NetLinx Master must first
be setup with either a Static IP or DHCP Address obtained from either NetLinx Studio
or your System Administrator.

Before commencing, verify you are using the latest NetLinx Master firmware.