5. Error resolution and daily maintenance

Error code list

Error code

Reason

Resolution

UUUUUU

Overflow:

measuring value is above FSD

+ overload range

1.Take off the goods from

scales

2.Recalibration

3. Check load cell

4.Chang main board

nnnnnn

Underflow:

measuring value is below

negative display range

1.Recalibration

2. Check load cell

3.Chang main board

ERR1

During calibration:

no enter the calibration weight

value

Input

weight

of

the

calibrated weights

ERR2

During calibration:

the used calibration weight

value is too low

Add weights.

Recommend the weights

is 15-80% the Max.

capacity

ERR3

During calibration:

input voltage is negative

1. Check the installation is

ok or not

2.Check the connection

for load cell is ok or not

ERR4

During calibration:

measuring

value

is

not

standstill

Check the scales

installation is ok and the

make sure the goods on

the scales is stable

ERR5

Checksum error of EEPROM

1.Power off the indicator

and re open again

2. Change main board

Lobat

The voltage of rechargeable

battery is too low

Recharge the battery