And weight &

“PCS” status light on. 4s latter automatically show

quantity

4.4 Indicator for livestock scales(animal scales)

When the indicator used for livestock scales. only set the digital

filter C13 1.and C14 2 is ok. steps as follows

1.Press

and

at the same time, enter into C13 by

pressing the

↑ ↓ ← → , press

for confirmation. Then the press

↑ key to change “ C13 0” to “ C13 3”. At last press

again

can enter into C14.

2. Press

. Enter into

” C14 3”. Change “C14 2” to “C14

1

” . and the setting for livestock scales finish.

Note: when for livestock weighing, set the digital filter 1 for C13.

The No. is bigger, the weighing will be more stable. And change is

slower.

Set the digital filter 2 for C14, The No. is smaller. The weighing

change faster. Adjust the C13 and C14 . can control the weighing

stability and speed suitable for animal weighing.

4.5 Classifying scales operation

The classifying function is optional, set the C20 C21 C22 C23 and it